Add to Cart
CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective time delay for Short-Circuit Protection
VKL11 Residual Current Circuit Breaker RCCB Type S Selective time delay
1. General
1.1 RCCB Function
Control electric circuits.
Protect people against indirect contacts and additional protection against direct contacts.
Protect installations against fire hazard due to insulation faults.
Residual current circuit breakers are used in housing, tertiary sector and industry.
1.2 RCCB Selection
Detectable wave form
AC class
Tripping is ensured for slowly increasing sinusoidal AC residual currents
A class
Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.
ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)
Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.
Note: Our ASi type includes G/KV function and Si function.
1.3 RCCB Approvals and certificates
We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying
with the requirements.
1. Verification of the operating characteristic as per Seq. - D0 CL9.9
2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16
3. High Voltage Test as per D.3 of Annex D
4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)
Tripping sensitivity
10mA - precision instrument leakage protection and bathroom use.
30mA - additional protection against direct contact.
100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;
300mA/500mA - protection against indirect contacts, as well as fire hazard.
Tripping time
Instantaneous
It ensures instantaneous tripping(without time-delay).
Short time delay ASi
(High Immunity/ Avoid nuisance tripping &blinding)
It ensures any tripping at least 10ms.
Selective
It ensures total discrimination with a non selective RCD placed downstream.
RCCB | Residual Current Circuit Breaker
2. Technical parameters
Standard | IEC/EN 61008-1 AS/NZS61008.1 | |
Electrical features | Model No. | VKL11 |
Poles | 2P, 4P | |
Rated current In | 16A, 25A, 32A, 40A, 63A, 80A, 100A | |
Rated Sensitivity I△n | 10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA | |
Rated voltage Ue | 2P: 240V 4P: 415V | |
Insulation voltage Ui | 415V | |
Rated frequency | 50/60 Hz | |
Rated residual making and breaking capacity I△m | 1500A | |
Short-circuit current Inc=I△c | 6000A, 10000A | |
Type (wave form of the earth leakage sensed) | AC, A, ASi, S | |
break time under I△n | ≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type) | |
Rated impulse withstand voltage(1.2/50) Uimp | 4kV | |
Dielectric test voltage at ind. Freq. for 1 min | 2.5 | |
Pollution degree | 2 | |
Mechanical features | Electrical life | ≥2000 |
Mechanical life | ≥2000 | |
Fault current indicator | Yes | |
Terminal protection degree | IP20 | |
Ambient temperature (with daily average≤35℃) | -25℃ to 50℃ | |
Storage temperate | -30℃ to 70℃ | |
Installation | Terminal connection type | Cable/Pin-type busbar |
Terminal size top/bottom for cable | 25-35 mm² | |
18-3/18-2 AWG | ||
Terminal size top/bottom for busbar | 10/16 mm² | |
18-8/18-5 AWG | ||
Tightening torque | 2.5 N·m | |
22 In-Ibs. | ||
Mounting | On DIN rail EN 60715 (35mm) by means of fast clip device | |
Connection | From top and bottom |
3. RCCB Outline and installation dimensions (mm)
The Residual Current Circuit Breaker (RCCB) with ISI mark NF SEMKO VDE KEMA is an innovative electrical protection device that is designed to protect people and property from electric shock and fire hazards. It is designed to detect and respond quickly to dangerous leakage currents, and it has a rated service short-circuit breaking capacity of 6kA, a rated impulse withstand voltage of 4kV, a rated operating frequency of 50/60Hz, a rated service impulse withstand voltage of 6kV, and a rated insulation voltage of 500V. This RCCB has been rigorously tested for safety and reliability and is approved by ISI mark NF SEMKO VDE KEMA. It provides reliable protection against damage or injury caused by electric shock or fire due to earth leakage current, overload current, and short-circuit current. The RCCB is suitable for residential, commercial, and industrial applications and is one of the most reliable and dependable circuit protection devices on the market.
HAROK VKL11 Residual Current Circuit Breaker (RCCB) is a reliable product certified by NF, SEMKO, VDE, KEMA, ISI, and CE. The minimum order quantity is 5000 pieces and the packaging is paper carton. The delivery time is 4-6 weeks after payment and the payment terms are FOB NINGBO or SHANGHAI. The rated current is 30mA-100mA and the rated service short-circuit breaking capacity is 6kA. The rated voltage is 240/415V AC and the rated frequency is 50/60Hz. Moreover, the rated insulation voltage is 500V. This product is ideal for applications requiring Residual Current Circuit Breaker type EV with an ISI mark, Residual Current Circuit Breaker NF SEMKO VDE KEMA, and other related applications, ensuring a high supply ability of 100,000 PCS per month.
Parameter | Value |
---|---|
Certification | NF SEMKO VDE KEMA |
Rated Current | 30mA-300mA |
Rated Operating Frequency | 50/60Hz |
Rated Ultimate Short-Circuit Breaking Capacity | 10kA |
Rated Insulation Voltage | 500V |
Rated Service Impulse Withstand Voltage | 6kV |
Rated Service Short-Circuit Breaking Capacity | 10kA |
Rated Impulse Withstand Voltage | 4kV |
Rated Short-Circuit Breaking Capacity | 10kA |
Rated Frequency | 50/60Hz |