Brand Name :HAROK
Model Number :VKL11
Place of Origin :CHINA
Certification :NF, SEMKO, VDE, KEMA, ISI, CE
MOQ :5000
Packaging Details :PAPER CARTON
Delivery Time :4-6 weeks after payment
Payment Terms :FOB NINGBO or SHANGHAI
Supply Ability :100,000 PCS PER MONTH
Rated Operating Frequency :50/60Hz
Rated Service Short-Circuit Breaking Capacity :6kA
Certificate :CE, ISI, NF, SEMKO, VDE, KEMA
Rated Residual Non-Operating Current :30mA, 100mA, 300mA
Rated Current :16A-300A
Rated Insulation Voltage :500V
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective time delay for Short-Circuit Protection

VKL11 Residual Current Circuit Breaker RCCB Type S Selective time delay

CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time Delay

1. General

1.1 RCCB Function

Control electric circuits.

Protect people against indirect contacts and additional protection against direct contacts.

Protect installations against fire hazard due to insulation faults.

Residual current circuit breakers are used in housing, tertiary sector and industry.

1.2 RCCB Selection

Detectable wave form

AC class

Tripping is ensured for slowly increasing sinusoidal AC residual currents

A class

Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.

ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

Note: Our ASi type includes G/KV function and Si function.

1.3 RCCB Approvals and certificates

We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

with the requirements.

1. Verification of the operating characteristic as per Seq. - D0 CL9.9

2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

3. High Voltage Test as per D.3 of Annex D

4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

Tripping sensitivity

10mA - precision instrument leakage protection and bathroom use.

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;

300mA/500mA - protection against indirect contacts, as well as fire hazard.

Tripping time

Instantaneous

It ensures instantaneous tripping(without time-delay).

Short time delay ASi

(High Immunity/ Avoid nuisance tripping &blinding)

It ensures any tripping at least 10ms.

Selective CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time Delay

It ensures total discrimination with a non selective RCD placed downstream.

CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time Delay

RCCB | Residual Current Circuit Breaker

2. Technical parameters

Standard IEC/EN 61008-1 AS/NZS61008.1
Electrical features Model No. VKL11
Poles 2P, 4P
Rated current In 16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Sensitivity I△n 10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
Rated voltage Ue 2P: 240V 4P: 415V
Insulation voltage Ui 415V
Rated frequency 50/60 Hz
Rated residual making and breaking capacity I△m 1500A
Short-circuit current Inc=I△c 6000A, 10000A
Type (wave form of the earth leakage sensed) AC, A, ASi, S
break time under I△n

≤0.1s(Normal type),

10ms~300ms(ASi type).

150ms~500ms(S type)

Rated impulse withstand voltage(1.2/50) Uimp 4kV
Dielectric test voltage at ind. Freq. for 1 min 2.5
Pollution degree 2
Mechanical features Electrical life ≥2000
Mechanical life ≥2000
Fault current indicator Yes
Terminal protection degree IP20

Ambient temperature (with

daily average≤35℃)

-25℃ to 50℃
Storage temperate -30℃ to 70℃
Installation Terminal connection type Cable/Pin-type busbar
Terminal size top/bottom for cable 25-35 mm²
18-3/18-2 AWG
Terminal size top/bottom for busbar 10/16 mm²
18-8/18-5 AWG
Tightening torque 2.5 N·m
22 In-Ibs.
Mounting On DIN rail EN 60715 (35mm) by means of fast clip device
Connection From top and bottom

3. RCCB Outline and installation dimensions (mm)

CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time DelayCE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time Delay

Product Description:

The Residual Current Circuit Breaker (RCCB) with ISI mark NF SEMKO VDE KEMA is an innovative electrical protection device that is designed to protect people and property from electric shock and fire hazards. It is designed to detect and respond quickly to dangerous leakage currents, and it has a rated service short-circuit breaking capacity of 6kA, a rated impulse withstand voltage of 4kV, a rated operating frequency of 50/60Hz, a rated service impulse withstand voltage of 6kV, and a rated insulation voltage of 500V. This RCCB has been rigorously tested for safety and reliability and is approved by ISI mark NF SEMKO VDE KEMA. It provides reliable protection against damage or injury caused by electric shock or fire due to earth leakage current, overload current, and short-circuit current. The RCCB is suitable for residential, commercial, and industrial applications and is one of the most reliable and dependable circuit protection devices on the market.

Features:

  • Product Name: Residual Current Circuit Breaker RCCB
  • Certification: NF SEMKO VDE KEMA
  • Type: Residual Current Circuit Breaker type S
  • Rated Operating Duration: ≤1s
  • Rated Voltage: 240/415V AC
  • Rated Operating Frequency: ≤0.2times/h
  • Rated Residual Current Off-Time: ≤0.1s
  • Rated Residual Operating Current: 30mA-300mA

Applications:

HAROK VKL11 Residual Current Circuit Breaker (RCCB) is a reliable product certified by NF, SEMKO, VDE, KEMA, ISI, and CE. The minimum order quantity is 5000 pieces and the packaging is paper carton. The delivery time is 4-6 weeks after payment and the payment terms are FOB NINGBO or SHANGHAI. The rated current is 30mA-100mA and the rated service short-circuit breaking capacity is 6kA. The rated voltage is 240/415V AC and the rated frequency is 50/60Hz. Moreover, the rated insulation voltage is 500V. This product is ideal for applications requiring Residual Current Circuit Breaker type EV with an ISI mark, Residual Current Circuit Breaker NF SEMKO VDE KEMA, and other related applications, ensuring a high supply ability of 100,000 PCS per month.

Technical Parameters:

Parameter Value
Certification NF SEMKO VDE KEMA
Rated Current 30mA-300mA
Rated Operating Frequency 50/60Hz
Rated Ultimate Short-Circuit Breaking Capacity 10kA
Rated Insulation Voltage 500V
Rated Service Impulse Withstand Voltage 6kV
Rated Service Short-Circuit Breaking Capacity 10kA
Rated Impulse Withstand Voltage 4kV
Rated Short-Circuit Breaking Capacity 10kA
Rated Frequency 50/60Hz

Customization:

Residual Current Circuit Breaker RCCB with ISI mark
  • Brand Name: HAROK
  • Model Number: VKL11
  • Place of Origin: CHINA
  • Certification: NF, SEMKO, VDE, KEMA, ISI, CE
  • Minimum Order Quantity: 5000
  • Packaging Details: PAPER CARTON
  • Delivery Time: 4-6 weeks after payment
  • Payment Terms: FOB NINGBO or SHANGHAI
  • Supply Ability: 100,000 PCS PER MONTH
  • Rated Service Short-Circuit Breaking Capacity: 10kA
  • Rated Ultimate Short-Circuit Breaking Capacity: 10kA
  • Rated Service Impulse Withstand Voltage: 6kV
  • Rated Impulse Withstand Voltage: 4kV

Packing and Shipping:

Packaging and Shipping for Residual Current Circuit Breaker (RCCB)

At our company, we package RCCBs in sturdy cardboard boxes with foam cushioning to protect against shock and vibration during transportation. Each box will contain one RCCB unit.

We use reliable and secure shipping services to deliver our products to customers around the world. Our shipments are always tracked and insured in case of any damage or theft.

Our company also offers custom packaging and shipping services for larger orders. We understand that your needs may vary, and we are committed to providing quality services to meet your specific requirements.

China CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time Delay for sale

CE Rated 10kA Residual Current Circuit Breaker RCCB Type S Selective Time Delay

Inquiry Cart 0