Add to Cart
Type F EV
Residual Current Circuit Breaker VKL11F TYPE F EV (RCCB TYPE F EV) is the Type EV RCCB which has been developed specifically for EV charging systems and can detect AC and DC residual currents in accordance with the requirements of EN61008-1 and EN62423(function for detecting smooth DC residual current and a tripping threshold of 6mA )
The VKL11F RCCB TYPE F EV also detects residual currents with mixed frequencies which is different from 50Hz. Electronic wiring and power electronics are required in electric vehicles for charging purposes. In the event of a fault, these can give rise to smooth DC residual currents and residual currents with mixed frequencies.The VKL11F RCCB TYPE F EV is also short-time delayed and has increased surge current strength. This significantly reduces the risk of faulty tripping.
Detectable wave form
AC class
Tripping is ensured for slowly increasing sinusoidal AC
residual currents
A class
Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.
Smooth DC 6mA
smooth DC residual currents (switch-off at max 6 mA)
1.3 Approvals and certificates :UKCA,CE
Tripping sensitivity
30mA - 50Hz sinusoidal AC ; Pulsating DC
Smooth DC ≥ 6 mA (RDC-PD)
Tripping time
short time delayed (G )
2. Outline and installation dimensions (mm)
3. Technical parameters
Standard | IEC/EN 61008-1 & EN62423 | |
Electrical features | Model No. | VKL11F F EV |
Poles | 2P, 4P | |
Rated current In | 16A, 25A, 32A, 40A, 63A, 80A, 100A | |
Rated Sensitivity I△n | 30mA | |
DC tripping threshold | 6mA | |
Rated voltage Ue | 2P: 240V 4P: 415V | |
Insulation voltage Ui | 500V | |
Rated frequency | 50/60 Hz | |
Rated residual making and breaking capacity I△m | 500A (In=16A, 25A, 32A, 40A) | |
630A(In=63A), 800A(In=80A), 1000A(In=100A) | ||
Short-circuit current Inc=I△c | 6000A, 10000A,1500 A | |
Rated making and breaking capacity Im Peak withstand current | 3 kA (8/20 μs) surge current proof | |
Type (wave form of the earth leakage sensed) | AC, A Smooth DC 6mA | |
Tripping time | Short time delayed | |
break time under I△n | 10ms~300ms (G,type) | |
Rated impulse withstand voltage(1.2/50) Uimp | 6kV | |
Dielectric test voltage at ind. Freq. for 1 min | 2.5 | |
Pollution degree | 2 | |
Mechanical features | Electrical life | ≥2000 |
Mechanical life | ≥2000 | |
Fault current indicator | Yes | |
Terminal protection degree | IP20 | |
Ambient temperature (with daily average≤35℃) | -25℃ to 55℃ | |
Storage temperature | -40℃ to 70℃ | |
Installation | Terminal connection type | Cable/Pin-type busbar |
Terminal size top/bottom for cable | 25-35 mm² | |
18-3/18-2 AWG | ||
Terminal size top/bottom for busbar | 10/16 mm² | |
18-8/18-5 AWG | ||
Tightening torque | 2.5 N·m | |
22 In-Ibs. | ||
Mounting | On DIN rail EN 60715 (35mm) by means of fast clip device | |
Connection | From top and bottom | |
Standard | EN61008-1 ,EN62423,OVE E8601 |
RCCB RDC-PD | Residual Current Circuit Breaker
The Residual Current Circuit Breaker (RCCB) is a high-performance electrical safety device designed to protect people and equipment from electrical shocks. It is certified by Inmetro, NF SEMKO, VDE, KEMA, and ISI mark, providing superior safety and reliability. It features a rated operating duration of no more than 1s, a rated frequency of 50/60Hz, a rated operating frequency of 50/60Hz, a rated service impulse withstand voltage of 6kV, making it a reliable and capable device. The RCCB is easy to install and maintain, and it is a reliable and cost-effective solution for ensuring safety in residential, commercial, and industrial settings.
HAROK VKL11 Residual Current Circuit Breaker RCCB type EV is the perfect solution for electrical safety at home. It is widely approved by NF, SEMKO, VDE, KEMA, ISI, CE, and Inmetro. With a minimum order quantity of 5000, the packaging details are paper carton. The delivery time is 4-6 weeks after payment and the payment terms are FOB NINGBO or SHANGHAI. HAROK VKL11 is capable of supplying 100,000 PCS per month. It has a rated operating frequency of 50/60Hz and a rated operating duration of ≤1s. The certificate is CE, ISI, NF, SEMKO, VDE, KEMA and the rated short-circuit breaking capacity is 10kA, and the rated residual operating current is from 30mA to 300mA.
Brand Name: HAROK
Model Number: VKL11
Place of Origin: CHINA
Certification: NF, SEMKO, VDE, KEMA, ISI, CE
Minimum Order Quantity: 5000
Packaging Details: PAPER CARTON
Delivery Time: 4-6 weeks after payment
Payment Terms: FOB NINGBO or SHANGHAI
Supply Ability: 100,000 PCS PER MONTH
Rated Service Impulse Withstand Voltage: 6kV
Rated Insulation Voltage: 500V
Rated Voltage: 240/415V AC
Certificate: CE, ISI, NF, SEMKO, VDE, KEMA
Our Residual Current Circuit Breaker RCCB features Inmetro certification, guaranteeing the safety of your household with the highest quality.
All our Residual Current Circuit Breaker RCCB products are certified with NF, SEMKO, VDE, KEMA, making sure that you get the best quality.
With ISI mark, you can assure that all our Residual Current Circuit Breakers RCCB are up to the highest international safety standards.
The Residual Current Circuit Breaker RCCB will be packaged and shipped carefully to ensure its safety during the transit.