Brand Name :HAROK
Model Number :VKL11
Place of Origin :CHINA
Certification :NF, SEMKO, VDE, KEMA, ISI, CE
MOQ :5000
Packaging Details :PAPER CARTON
Delivery Time :4-6 weeks after payment
Payment Terms :FOB NINGBO or SHANGHAI
Supply Ability :100,000 PCS PER MONTH
Rated Residual Operating Current :30mA-100mA
Rated Service Impulse Withstand Voltage :6kV
Certificate :CE, ISI, NF, SEMKO, VDE, KEMA
Rated Operating Duration :≤1s
Rated Service Short-Circuit Breaking Capacity :6kA
Rated Ultimate Short-Circuit Breaking Capacity :10kA
Rated Voltage :230V AC
Rated Operating Frequency :≤0.2times/h
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

VKL11 RCCB Residual Current Circuit Breaker break time under I△n 10ms~300ms type G short-time delay

VKL11 Residual Current Circuit Breaker RCCB TYPE G short-time delay

16A 25A 2pole RCCB TYPE G Short Time Delay VKL11 For EV Charging Systems

1. General

1.1 Function

Residual Current Circuit Breaker VKL11F TYPE F EV (RCCB TYPE F EV) is the Type EV RCCB which has been developed specifically for EV charging systems and can detect AC and DC residual currents in accordance with the requirements of EN61008-1 and EN62423(function for detecting smooth DC residual current and a tripping threshold of 6mA )

The VKL11F RCCB TYPE F EV also detects residual currents with mixed frequencies which is different from 50Hz. Electronic wiring and power electronics are required in electric vehicles for charging purposes. In the event of a fault, these can give rise to smooth DC residual currents and residual currents with mixed frequencies.The VKL11F RCCB TYPE F EV is also short-time delayed and has increased surge current strength. This significantly reduces the risk of faulty tripping.

1.2 Selection

Detectable wave form

AC class

Tripping is ensured for slowly increasing sinusoidal AC

residual currents

A class

Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.

Smooth DC 6mA

smooth DC residual currents (switch-off at max 6 mA)


16A 25A 2pole RCCB TYPE G Short Time Delay VKL11 For EV Charging Systems16A 25A 2pole RCCB TYPE G Short Time Delay VKL11 For EV Charging Systems

1.3 Approvals and certificates :UKCA,CE

Tripping sensitivity

30mA - 50Hz sinusoidal AC ; Pulsating DC

Smooth DC ≥ 6 mA (RDC-PD)

Tripping time

short time delayed (G )

2. Outline and installation dimensions (mm)

16A 25A 2pole RCCB TYPE G Short Time Delay VKL11 For EV Charging Systems16A 25A 2pole RCCB TYPE G Short Time Delay VKL11 For EV Charging Systems

3. Technical parameters

Standard IEC/EN 61008-1 & EN62423
Electrical features Model No. VKL11
Poles 2P, 4P
Rated current In 16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Sensitivity I△n 30mA
DC tripping threshold 6mA
Rated voltage Ue 2P: 240V 4P: 415V
Insulation voltage Ui 500V
Rated frequency 50/60 Hz

Rated residual making and

breaking capacity I△m

500A (In=16A, 25A, 32A, 40A)
630A(In=63A), 800A(In=80A), 1000A(In=100A)
Short-circuit current Inc=I△c 6000A, 10000A,1500 A

Rated making and breaking capacity Im

Peak withstand current

3 kA (8/20 μs) surge current proof
Type (wave form of the earth leakage sensed)

AC, A

Smooth DC 6mA

Tripping time Short time delayed
break time under I△n

10ms~300ms

(G,type)

Rated impulse withstand voltage(1.2/50) Uimp 6kV
Dielectric test voltage at ind. Freq. for 1 min 2.5
Pollution degree 2
Mechanical features Electrical life ≥2000
Mechanical life ≥2000
Fault current indicator Yes
Terminal protection degree IP20

Ambient temperature (with

daily average≤35℃)

-25℃ to 55℃
Storage temperature -40℃ to 70℃
Installation Terminal connection type Cable/Pin-type busbar
Terminal size top/bottom for cable 25-35 mm²
18-3/18-2 AWG
Terminal size top/bottom for busbar 10/16 mm²
18-8/18-5 AWG
Tightening torque 2.5 N·m
22 In-Ibs.
Mounting On DIN rail EN 60715 (35mm) by means of fast clip device
Connection From top and bottom
Standard EN61008-1 ,EN62423,OVE E8601

Product Description:

Residual Current Circuit Breaker Inmetro (RCCB) is a device designed to protect people from electric shock and fire caused by short circuits and leakage currents. It is certified by CE, ISI, NF, SEMKO, VDE and KEMA and has a rated residual operating current ranging from 30mA to 300mA, a rated current ranging from 16A to 100A, and a rated voltage of 230V AC. In addition, its rated operating duration is no more than 1s. RCCB is highly reliable and can effectively protect people from electric shock and fire.

Features:

  • Product Name: Residual Current Circuit Breaker RCCB
  • Type: Residual Current Circuit Breaker type F EV
  • Mark: Residual Current Circuit Breaker with ISI mark
  • Rated Voltage: 240/415V AC
  • Rated Insulation Voltage: 500V
  • Rated Impulse Withstand Voltage: 4kV
  • Rated Residual Operating Current: 30mA-300mA
  • Rated Service Impulse Withstand Voltage: 6kV

Applications:

HAROK VKL11 Residual Current Circuit Breaker RCCB is a reliable safety device used to protect people and properties from electrical shock, electrical fire and other hazardous conditions. It is certified by Inmetro, NF SEMKO VDE KEMA, ensuring that it meets the highest safety standards. It is designed with high-performance features and is convenient to install, making it the perfect choice for residential, commercial and industrial applications.

HAROK VKL11 RCCB is rated for a frequency of 50/60Hz, a short-circuit breaking capacity of 10kA and a rated voltage of 240/415V AC. In addition, it has a rated ultimate short-circuit breaking capacity of 10kA, providing an exceptionally reliable safety device. It is also easy to maintain and has a long service life.

HAROK VKL11 RCCB is available in a minimum order quantity of 5000 units. It is delivered in a paper carton and can be shipped within 4-6 weeks after payment. It is available with a CE, ISI, NF, SEMKO, VDE and KEMA certificate and can be purchased on FOB NINGBO or SHANGHAI terms with a maximum supply capacity of 100,000 PCS PER MONTH.

Technical Parameters:

Parameter Value
Rated Short-Circuit Breaking Capacity 10kA
Rated Frequency 50/60Hz
Rated Insulation Voltage 500V
Rated Ultimate Short-Circuit Breaking Capacity 10kA
Rated Residual Operating Current 30mA-300mA
Rated Voltage 240/415V AC
Rated Residual Current Off-Time ≤0.1s
Rated Service Impulse Withstand Voltage 6kV
Rated Impulse Withstand Voltage 4kV

Customization:

Residual Current Circuit Breaker RCCB

Brand Name: HAROK

Model Number: VKL11

Place of Origin: CHINA

Certification: NF, SEMKO, VDE, KEMA, ISI, CE

Minimum Order Quantity: 5000

Packaging Details: PAPER CARTON

Delivery Time: 4-6 weeks after payment

Payment Terms: FOB NINGBO or SHANGHAI

Supply Ability: 100,000 PCS PER MONTH

Residual Current Circuit Breaker Inmetro, Residual Current Circuit Breaker NF SEMKO VDE KEMA , Residual Current Circuit Breaker Inmetro ISI CE

Rated Service Impulse Withstand Voltage: 6kV

Rated Operating Frequency: 50/60Hz

Rated Current: 16A-100A

Rated Residual Operating Current: 30mA-300mA

Rated Frequency: 50/60Hz

Packing and Shipping:

Packaging and Shipping

Residual Current Circuit Breaker (RCCB) products should be properly packaged and shipped in order to ensure their safe delivery. The following guidelines should be followed for packaging and shipping RCCB products:

  • Pack the RCCB products in the original manufacturer's packaging or a similarly durable packaging material to protect the product.
  • Ensure that the package is labeled clearly with the RCCB product name, part number, and the shipping address.
  • Securely seal the package with tape or other appropriate sealing methods.
  • Ship the package through an appropriate shipping service that provides tracking.
  • Provide the tracking number to the customer.
China 16A 25A 2pole RCCB TYPE G Short Time Delay VKL11 For EV Charging Systems for sale

16A 25A 2pole RCCB TYPE G Short Time Delay VKL11 For EV Charging Systems

Inquiry Cart 0