HAROK 50/60 Hz 40a 100ma RCCB Inmetro 240V 415V rccb in electrical

China HAROK 50/60 Hz 40a 100ma RCCB Inmetro 240V 415V rccb in electrical wholesale
  • China HAROK 50/60 Hz 40a 100ma RCCB Inmetro 240V 415V rccb in electrical wholesale

HAROK 50/60 Hz 40a 100ma RCCB Inmetro 240V 415V rccb in electrical

Ask Latest Price
Video Channel
Brand Name :HAROK
Model Number :VML01
Place of Origin :CHINA
MOQ :3000PCS
Payment Terms :L/C, T/T, Western Union, MoneyGram
Product Name :Residual Current Circuit Breaker
Model :VML01
Rated current :16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated voltage :2P: 240V 4P: 415V
Rated frequency :50/60 Hz
Terminal connection type :Cable/Pin-type busbar
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

HAROK 50/60 Hz 40a 100ma RCCB Inmetro 240V 415V rccb in electrical

VML01 Residual Current Circuit Breaker RCCB Inmetro​

HAROK 50/60 Hz 40a 100ma RCCB Inmetro 240V 415V rccb in electrical

1. General

1.1 Function

Control electric circuits.

Protect people against indirect contacts and additional protection against direct contacts.

Protect installations against fire hazard due to insulation faults.

Residual current circuit breakers are used in housing, tertiary sector and industry.

1.2 Selection

Detectable wave form

AC class

Tripping is ensured for slowly increasing sinusoidal AC residual currents

A class

Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.

ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

Note: Our ASi type includes G/KV function and Si function.

1.3 Approvals and certificates

We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

with the requirements.

1. Verification of the operating characteristic as per Seq. - D0 CL9.9

2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

3. High Voltage Test as per D.3 of Annex D

4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

Tripping sensitivity

10mA - precision instrument leakage protection and bathroom use.

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;

300mA/500mA - protection against indirect contacts, as well as fire hazard.

Tripping time

Instantaneous

It ensures instantaneous tripping(without time-delay).

Short time delay ASi

(High Immunity/ Avoid nuisance tripping &blinding)

It ensures any tripping at least 10ms.

Selective HAROK 50/60 Hz 40a 100ma RCCB Inmetro 240V 415V rccb in electrical

It ensures total discrimination with a non selective RCD placed downstream.

HAROK 50/60 Hz 40a 100ma RCCB Inmetro 240V 415V rccb in electrical

RCCB | Residual Current Circuit Breaker

2. Technical parameters

Standard IEC/EN 61008-1 AS/NZS61008.1
Electrical features Model No. VML01
Poles 2P, 4P
Rated current In 16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Sensitivity I△n 10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
Rated voltage Ue 2P: 240V 4P: 415V
Insulation voltage Ui 415V
Rated frequency 50/60 Hz
Rated residual making and breaking capacity I△m 1500A
Short-circuit current Inc=I△c 6000A, 10000A
Type (wave form of the earth leakage sensed) AC, A, ASi, S
break time under I△n ≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
Rated impulse withstand voltage(1.2/50) Uimp 4kV
Dielectric test voltage at ind. Freq. for 1 min 2.5
Pollution degree 2
Mechanical features Electrical life ≥2000
Mechanical life ≥2000
Fault current indicator Yes
Terminal protection degree IP20

Ambient temperature (with

daily average≤35℃)

-25℃ to 50℃
Storage temperate -30℃ to 70℃
Installation Terminal connection type Cable/Pin-type busbar
Terminal size top/bottom for cable 25-35 mm²
18-3/18-2 AWG
Terminal size top/bottom for busbar 10/16 mm²
18-8/18-5 AWG
Tightening torque 2.5 N·m
22 In-Ibs.
Mounting On DIN rail EN 60715 (35mm) by means of fast clip device
Connection From top and bottom

3. RCCB Outline and installation dimensions (mm)

HAROK 50/60 Hz 40a 100ma RCCB Inmetro 240V 415V rccb in electrical

China HAROK 50/60 Hz 40a 100ma RCCB Inmetro 240V 415V rccb in electrical for sale

HAROK 50/60 Hz 40a 100ma RCCB Inmetro 240V 415V rccb in electrical