Yueqing Vorax Electric CO.,LTD

Empowering Safety Energizing Efficiency Your Trusted Breaker Partner

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Residual Current Circuit Breaker RCCB /

50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater

China 50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater wholesale
  • China 50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater wholesale
  • China 50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater wholesale
  • China 50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater wholesale

50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater

Ask Latest Price
Video Channel
Brand Name :HAROK
Model Number :VFL001
Place of Origin :CHINA
Certification :NF, SEMKO, VDE, KEMA, ISI, CE
MOQ :5000
Packaging Details :PAPER CARTON
Delivery Time :4-6 weeks after payment
Payment Terms :FOB NINGBO or SHANGHAI
Supply Ability :100,000 PCS PER MONTH
Rated voltage Ue :2P: 240V 4P: 415V
Rated Frequency :50/60Hz
Rated Sensitivity I△n :10mA(2P/4P 16A-40A), 30mA, 100mA, 300mA
Rated Service Impulse Withstand Voltage :6kV
Rated current In :16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Ultimate Short-Circuit Breaking Capacity :10kA
Certificate :CE, ISI, NF, SEMKO, VDE, KEMA
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

VFL001 Rated 6kA Service Short-Circuit Breaking Capacity Residual Current Circuit Breaker (RCCB)

VFL001 Residual Current Circuit Breaker(RCCB) Type A Type AC Type ASi

50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater

1. General

1.1 Function

Control electric circuits.

Protect people against indirect contacts and additional protection against direct contacts.

Protect installations against fire hazard due to insulation faults.

Residual current circuit breakers are used in housing, tertiary sector and industry.

1.2 Selection

Detectable wave form

AC class

Tripping is ensured for slowly increasing sinusoidal AC residual currents

A class

Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.

ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

Note: Our ASi type includes G/KV function and Si function.

1.3 Approvals and certificates

We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

with the requirements.

1. Verification of the operating characteristic as per Seq. - D0 CL9.9

2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

3. High Voltage Test as per D.3 of Annex D

4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

Tripping sensitivity

10mA - precision instrument leakage protection and bathroom use.

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;

300mA/500mA - protection against indirect contacts, as well as fire hazard.

Tripping time

Instantaneous

It ensures instantaneous tripping(without time-delay).

Short time delay ASi

(High Immunity/ Avoid nuisance tripping &blinding)

It ensures any tripping at least 10ms.

Selective 50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater

It ensures total discrimination with a non selective RCD placed downstream.

50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater

RCCB | Residual Current Circuit Breaker

2. Technical parameters

Standard IEC/EN 61008-1 AS/NZS61008.1
Electrical features Model No. VFL001
Poles 2P, 4P
Rated current In 16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Sensitivity I△n 10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
Rated voltage Ue 2P: 240V 4P: 415V
Insulation voltage Ui 415V
Rated frequency 50/60 Hz
Rated residual making and breaking capacity I△m 1500A
Short-circuit current Inc=I△c 6000A, 10000A
Type (wave form of the earth leakage sensed) AC, A, ASi, S
break time under I△n ≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
Rated impulse withstand voltage(1.2/50) Uimp 4kV
Dielectric test voltage at ind. Freq. for 1 min 2.5
Pollution degree 2
Mechanical features Electrical life ≥2000
Mechanical life ≥2000
Fault current indicator Yes
Terminal protection degree IP20

Ambient temperature (with

daily average≤35℃)

-25℃ to 50℃
Storage temperate -30℃ to 70℃
Installation Terminal connection type Cable/Pin-type busbar
Terminal size top/bottom for cable 25-35 mm²
18-3/18-2 AWG
Terminal size top/bottom for busbar 10/16 mm²
18-8/18-5 AWG
Tightening torque 2.5 N·m
22 In-Ibs.
Mounting On DIN rail EN 60715 (35mm) by means of fast clip device
Connection From top and bottom

3. Outline and installation dimensions (mm)

50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater

Product Description:

Residual Current Circuit Breaker type A, type AC, type ASi is a reliable and safe product with a wide range of applications. It is designed to provide protection against electric shock due to leakage currents, as well as to detect short circuits and overloads. The RCCB has a rated voltage of 230V AC, and a rated current of 30mA-100mA. It is certified to meet the highest safety standards, including CE, ISI, NF, SEMKO, VDE, and KEMA. The RCCB with ISI mark has been tested and approved by the Indian Standard Institute, and the Residual Current Circuit Breaker Inmetro is certified by the Brazilian National Institute of Metrology, Quality, and Technology. The Residual Current Circuit Breaker with CE mark is compliant with the European Union's safety regulations. It has a rated operating duration of ≤1s and a rated operating frequency of 50/60Hz, providing superior protection against electric shock.

Features:

  • Product Name: Residual Current Circuit Breaker RCCB
  • Certifications: NF SEMKO VDE KEMA, Residual Current Circuit Breaker with ISI mark
  • Rated Residual Operating Current: 10mA-300mA
  • Rated Service Impulse Withstand Voltage: 6kV
  • Rated Service Short-Circuit Breaking Capacity: 10kA
  • Rated Residual Current Off-Time: ≤0.1s
  • Rated Current: 16A-100A

Applications:

HAROK VFL001 Residual Current Circuit Breaker RCCB with Inmetro certification is an ideal device for protecting people from electric shock and fire risks, as it can detect and isolate the fault current immediately with its rated current 30mA-100mA and insulation voltage 500V. It is certified by NF, SEMKO, VDE, KEMA, ISI, CE and has a rated service impulse withstand voltage of 6kV, rated short-circuit breaking capacity of 10kA, which makes it suitable for different applications. With a minimum order quantity of 5000 pieces, the product can be delivered in 4-6 weeks after payment, and the paper carton packaging ensures the safety of the products. With the ability to produce 100,000 pieces per month, HAROK VFL001 Residual Current Circuit Breaker RCCB is the perfect choice for any residential, commercial and industrial applications.

Technical Parameters:

Parameter Value
Rated Short-Circuit Breaking Capacity 10kA
Rated Service Short-Circuit Breaking Capacity 10kA
Certificate CE, ISI, NF, SEMKO, VDE, KEMA
Rated Residual Current Off-Time ≤0.1s
Rated Insulation Voltage 500V
Rated Ultimate Short-Circuit Breaking Capacity 10kA
Rated Residual Operating Current 30mA-300mA
Rated Voltage 240/415V AC
Rated Frequency 50/60Hz

Customization:

Residual Current Circuit Breaker RCCB with ISI Mark
  • Brand Name: HAROK
  • Model Number: VFL001
  • Place of Origin: CHINA
  • Certification: NF, SEMKO, VDE, KEMA, ISI, CE
  • Minimum Order Quantity: 5000
  • Packaging Details: PAPER CARTON
  • Delivery Time: 4-6 weeks after payment
  • Payment Terms: FOB NINGBO or SHANGHAI
  • Supply Ability: 100,000 PCS PER MONTH
  • Certificate: CE, ISI, NF, SEMKO, VDE, KEMA
  • Rated Ultimate Short-Circuit Breaking Capacity: 10kA
  • Rated Voltage: 240/415V AC
  • Rated Impulse Withstand Voltage: 4kV
  • Rated Current: 30mA-300mA

Packing and Shipping:

Packaging and Shipping of Residual Current Circuit Breaker RCCB

Residual Current Circuit Breaker RCCB is usually packaged in a single box that contains the breaker, instruction manual, and all necessary accessories. The box is then wrapped in a plastic bag for protection against moisture and dust.

The package should also include a packing slip with the order number, delivery address, product information, and any other pertinent information.

The package should be labeled with the product name, item number, customer name, and any other relevant information.

The package should be securely packaged for shipping. The box should be sealed using tape and should be clearly labeled with the shipper's address and any other relevant information.

Shipping should be done using a reliable carrier service. The package should be insured to ensure the safety of the product during transit. Tracking information should be provided to the customer so they can follow the package's progress.

China 50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater for sale

50/60Hz 2P 4P Electrical Residual Current Circuit Breaker RCCB For Water Heater

Inquiry Cart 0