VRL11 Residual Current Operated Circuit Breaker With Over-Current Protection With 3-5In B Type Tripping Curve

Ask Latest Price
Video Channel
Brand Name :HAROK
Model Number :VRL11
Place of Origin :CHINA
MOQ :3000PCS
Payment Terms :L/C, T/T
Poles number :1P+N
Rated voltage :2P: 230/240V AC 4P: 400/415V AC
Mechanical life :2000
Standard :IEC/EN 62423, IEC/EN 61009-1, OVE E8601
Rated frequency :50/60Hz
Rated Current :6A,10A,13A,16A, 20A,25A, 32A, 40A, 63A
Electrical life :2000
CURVE :TYPE B
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

VRL11 Residual Current Operated Circuit Breaker With Over-Current Protection With 3-5In B Type Tripping CurveTYPE B RCBO | Residual Current Operated Circuit Breaker with over-current protection

VRL11 Residual Current Operated Circuit Breaker with over-current protection TYPE B and TYPE B+

(MCB sized 1 module with switched neutral)

1. General

VRL11B RCBO type B and VRL11B+ RCBO type B+ are appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker with Overcurrent protection(RCBO).

Rated current up to 63A and for purposes of residual current protection, overcurrent (overload) and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the RCBO can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be operated.

Residual current circuit breaker with Overcurrent protection(RCBO) type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

Residual current circuit breaker with Overcurrent protection(RCBO) type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.

1.2 Selection

Detectable wave form

Type B

Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

Type B+

Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA

Tripping sensitivity

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide

protection against indirect contacts;

300mA - protection against indirect contacts, as well as fire hazard.

Tripping time

Instantaneous It ensures instantaneous tripping(without time-delay).

Short time delay

Selective (time delay)

Tripping Curve B & C

VRL11 Residual Current Operated Circuit Breaker With Over-Current Protection With 3-5In B Type Tripping Curve

1.3 Approvals and certificates

CE

  • Technical parameters

2.1 Basic parameters

Type B B+
Electrical
Design according to IEC/EN 62423, IEC/EN 61009-1, OVE E8601
VDE 0664-400
Current test marks as printed onto the device
Rated voltage Un

2P: 230/240V AC

4P: 400/415V AC

Rated frequency fn 50/60Hz
Mode of operation

"A type functionality: voltage independent

B and B+ type functionality: voltage dependent"

Operation voltage electronic 50 – 264V AC
Voltage range test circuit

2P: 184 – 264V AC

4P: 184 – 440V AC

Rated current In 6A,10A,13A,16A, 20A,25A, 32A, 40A, 63A

Rated residual

operating

current I△n

Instantaneous 30mA, 100mA, 300mA, 500mA 30mA, 100mA, 300mA
K-short time delayed (G, ASi) 30mA, 100mA, 300mA, 500mA 30mA, 100mA, 300mA
S- selective 100mA, 300mA, 500mA 100mA, 300mA
Sensitivity Alternating, pulsed and smooth direct currents
High frequency up to 1 kHZ High frequency up to 20kHZ
Tripping Curve B: (3-5)In, C: (5-10)In
Rated insulation voltage Ui 500 V
Rated impulse withstand voltage Uimp 4 kV (1.2/50μs)
Rated conditional short-circuit current Inc 6KA,10 kA
Rated making and breaking capacity Im 3000 A
Peak withstand current

3 kA (8/20 μs) surge current proof

5 kA (8/20 μs) surge current proof for type S

Electrical isolation > 4 mm contact space

Endurance

(operating cycles)

electrical components ≥ 2000
mechanical components ≥ 4000
Mechanical
Degree of protection IP20
Upper and lower terminals open mounted / lift terminals
Terminal capacity 1 - 25 mm2
Terminal torque 2 - 2.5 Nm
Busbar thickness 0.8 - 2 mm
Operating temperature -25°C ... +55°C
Storage- and transport temperature -40°C ... +70°C
Resistance to climatic conditions IEC/EN 61009
Contact position indicator mechanical red / green
Supply possibility top or bottom
Mounting position any

2.2 The residual current breaking times

In (A) I△n (A) Breaking time when the residual current assumes the following values (s)
I△n 2I△n 5I△n 5A, 10A, 20A, 50A, 100A, 200A, 500A(a) I△t(b)
6~63 0.01, 0.03, 0.1, 0.3, 0.5 0.1 0.05 0.04 0.04 0.04

a. For tests of 5A, 10A, 20A, 50A, 100A, 200A and 500A, the current values beyond the lower limit of over-current instantaneous tripping are not tested.

B. Tests are done when I△t is equal to the lower limit current of over-current instantaneous tripping of type B and type C.

2.3 The over-current protection characteristics

No. Rated current In (A) Initial state Test current (A) Specified time (t) Expected result Remarks
a 6 ~ 63 Cold state 1.13 In t ≥ 1h Non-tripping
b Immediately after sequence a 1.45 In t < 1h Tripping Increase to the specified current within 5s after test item a.
c Cold state 2.55 In 1s < t < 60s Tripping
d Cold state 3 In t ≥ 0.1s Non-tripping Curve B
5 In t < 0.1s Tripping
5 In t ≥ 0.1s Non-tripping Curve C
10 In t < 0.1s Tripping

3. Outline and installation dimensions (mm)

VRL11 Residual Current Operated Circuit Breaker With Over-Current Protection With 3-5In B Type Tripping Curve

Product Description:

RCBO Type B is a high-performance product that offers superior mechanical and electrical life of 2000. It has a frame size rated current of Inm 50A, and meets the rigorous standards of IEC/EN 61009-1, AS/NZS 61009.1. It also has a rated impulse withstand voltage of Uimp 6000V, ensuring maximum safety and reliability. RCBO Type B is the perfect choice for high-end applications that demand maximum performance and reliability.

Features:

  • Product Name: RCBO Type B
  • Frame size rated current Inm: 50A
  • Rated impulse withstand voltage Uimp: 6000V
  • Rated Residual Non-Operating Current: 0.005A, 0.015A, 0.05A, 0.15A
  • Type of Instantaneous Tripping: Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
  • Residual Current Operated Circuit Breaker (RCBO)
  • Circuit Breaker with Overcurrent Protection

Applications:

HAROK's RCBO Type B provides reliable protection for industrial and commercial applications. Its rated residual non-operating current of 0.005A, 0.015A, 0.05A, 0.15A and Rated residual making and breaking capacity I△m of 500A provides a safe and optimal operating environment. This product is available in 1P+N poles and classified by Type of Instantaneous Tripping. Type B: (3 ~ 5) In and Type C: (5 ~ 10) In. The model numbers are VRL22 2P,4P VRL11 VAL003 VKL003 VDL006 VRL01 VRL02 VRL03 VK007LE 1P-4P. It is manufactured in China and is highly reliable for protection against electrical shock and fire.

Technical Parameters:

Parameter Value
Standard IEC/EN 61009-1, AS/NZS 61009.1
Rated Voltage AC240V
Rated residual making and breaking capacity I△m 500A
Rated impulse withstand voltage Uimp 6000V
Classified by Type of Instantaneous Tripping Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
Frame size rated current Inm 50A
Rated Residual Operating Current 0.01A, 0.03A, 0.1A, 0.3A
Connection From Top And Bottom, From Bottom And Top
Product Name RCBO Type B
Type Type B

Customization:

RCBO Type B by HAROK

Brand Name: HAROK
Model Number: VRL22 2P,4P VRL11 VAL003 VKL003 VDL006 VRL01 VRL02 VRL03 VK007LE 1P-4P
Place of Origin: CHINA
Frame size rated current Inm: 50A
Rated Current: 6A 10A 16A 20A 25A 32A 40A 50A
Classified by Type of Instantaneous Tripping: Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
Rated Residual Operating Current: 0.01A, 0.03A, 0.1A, 0.3A
Rated residual making and breaking capacity I△m: 500A

RCBO circuit breaker is a protective device that combines the functions of a residual current device and a circuit breaker. It is used as over-current protection in residential and commercial applications. HAROK's RCBO Type B is designed with a quick trip time for protecting against electrical shocks. It offers 6A, 10A, 16A, 20A, 25A, 32A, 40A, and 50A rated current, and is able to withstand 500A of rated residual making and breaking capacity.

Support and Services:

Technical support and service for RCBO Type B products include:

  • Guidance on product selection and installation
  • Product inquiries, troubleshooting and repairs
  • Software and firmware updates
  • Technical documentation and resources
  • Product maintenance and service plans
  • Product recalls and safety notices

Packing and Shipping:

Packaging and Shipping of RCBO Type B

The RCBO Type B is packaged in a cardboard box. The box is made of corrugated cardboard and is suitable for shipping. The size of the box is 40cm x 30cm x 20cm. Inside the box, the RCBO Type B is securely packaged with bubble wrap and foam. It is then sealed with tape. The box is then labeled with the product name, item number, and shipping address.

FAQ:

Q: What is RCBO Type B?
A: RCBO Type B is a residual current circuit breaker with over-current protection (RCBO) produced by HAROK. It has a model number of VRL22 2P,4P VRL11 VAL003 VKL003 VDL006 VRL01 VRL02 VRL03 VK007LE 1P-4P and is made in China.
Q: What are the benefits of using HAROK RCBO Type B?
A: HAROK RCBO Type B provides protection from overloads and short circuits, as well as residual current protection for the electrical circuit, enhancing safety and reliability.
Q: What types of applications is RCBO Type B suitable for?
A: HAROK RCBO Type B is suitable for different types of residential, commercial and industrial applications.
Q: What is the operating temperature range of the HAROK RCBO Type B?
A: The operating temperature range of HAROK RCBO Type B is -25°C to 40°C.
Q: What is the maximum breaking capacity of the HAROK RCBO Type B?
A: The maximum breaking capacity of HAROK RCBO Type B is 10kA.

Inquiry Cart 0