Yueqing Vorax Electric CO.,LTD

Empowering Safety Energizing Efficiency Your Trusted Breaker Partner

Manufacturer from China
Verified Supplier
3 Years
Home / Products / RCD TYPE B /

Super Immunised Residual Current Device Type B

Contact Now
Yueqing Vorax Electric CO.,LTD
Visit Website
Province/State:zhejiang
Country/Region:china
Contact Person:MrWellkins Lew
Contact Now

Super Immunised Residual Current Device Type B

Ask Latest Price
Video Channel
Brand Name :HAROK
Model Number :VKL11
Place of Origin :CHINA
Certification :CE, CB, NF, ISI, SEMKO
MOQ :5000
Packaging Details :PAPER CARTON
Delivery Time :4-6 weeks after payment
Payment Terms :FOB NINGBO or SHANGHAI
Supply Ability :100,000 PCS PER MONTH
Rated Residual Operating Time :0.03s
Operating Temperature :-25℃~+55℃
Rated Storage Temperature :-40℃~+70℃
Rated Frequency :50Hz/60Hz
Rated residual operating current I△n :30mA, 100mA, 300mA, 500mA
Rated current In :16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated conditional short-circuit current Inc :10kA
Product Name :Residual Current Device TYPE B
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Super immunised Residual Current Device Type B

  • General

1.1 Function

VKL11B RCD and VKL11B+ RCD is appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker.

Residual current circuit breaker type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

Residual current circuit breaker type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.

1.2 Selection

Detectable wave form

Type B

Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

Type B+

Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA

Tripping sensitivity

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide

protection against indirect contacts;

300mA - protection against indirect contacts, as well as fire hazard.

Tripping time

Instantaneous It ensures instantaneous tripping(without time-delay).

Short time delay

Selective (time delay)

1.3 Approvals and certificates

  • Technical parameters
Type B B+
Electrical
Design according to IEC/EN 62423, IEC/EN 61008-1, OVE E8601
VDE 0664-400
Current test marks as printed onto the device
Rated voltage Un

2P: 230/240V AC

4P: 400/415V AC

Rated frequency fn 50/60Hz
Mode of operation

"A type functionality: voltage independent

B and B+ type functionality: voltage dependent"

Operation voltage electronic 50 – 264V AC
Voltage range test circuit

2P: 184 – 264V AC

4P: 184 – 440V AC

Rated current In 16A, 25A, 32A, 40A, 63A, 80A, 100A

Rated residual

operating

current I△n

Instantaneous 30mA, 100mA, 300mA, 500mA 30mA, 100mA, 300mA
K-short time delayed (G, ASi) 30mA, 100mA, 300mA, 500mA 30mA, 100mA, 300mA
S- selective 100mA, 300mA, 500mA 100mA, 300mA
Sensitivity Alternating, pulsed and smooth direct currents
High frequency up to 1 kHZ High frequency up to 20kHZ
Rated insulation voltage Ui 500 V
Rated impulse withstand voltage Uimp 4 kV (1.2/50μs)
Rated conditional short-circuit current Inc 10 kA
Rated making and breaking capacity Im 1500 A
Peak withstand current

3 kA (8/20 μs) surge current proof

5 kA (8/20 μs) surge current proof for type S

Electrical isolation > 4 mm contact space

Maximum back-up fuse

In = 16-100A

Short circuit and overload protection

100 A gG/gL

Endurance

(operating cycles)

electrical components ≥ 2000
mechanical components ≥ 4000
Mechanical
Degree of protection IP20
Upper and lower terminals open mounted / lift terminals
Terminal capacity 1 - 25 mm2
Terminal torque 2 - 2.5 Nm
Busbar thickness 0.8 - 2 mm
Operating temperature -25°C ... +55°C
Storage- and transport temperature -40°C ... +70°C
Resistance to climatic conditions IEC/EN 61008
Contact position indicator mechanical red / green
Supply possibility top or bottom
Mounting position any

  • Special features regarding the use of SIQUENCE universal current-sensitive residual current circuit breaker (Type B and Type B+)
    • Applications

3.1 Typical applications that are vulnerable to smooth DC residual currents:

- Frequency converters with a three-phase connection

- Medical equipment such as X-ray equipment or CT machines

- Photovoltaic or UPS systems

- Connection points (wall boxes, charging stations) for electric vehicles

- Elevator controllers

- Pipeline trace heating

- Test setups in laboratories

- Construction sites in accordance with BGI 608 information leaflet (Electronic equipment

on construction sites)

- Charging stations for battery-powered forklift trucks

- Cranes of all kinds

- Mixing plants if relevant loads are connected

- Variable-speed machine tools, such as milling and grinding machines or lathes

  • Wiring diagrams

Super Immunised Residual Current Device Type BSuper Immunised Residual Current Device Type B

  • Tripping characteristics

.B type

Super Immunised Residual Current Device Type B

  • Dimensions (mm)
  • Super Immunised Residual Current Device Type BSuper Immunised Residual Current Device Type B

Product Description:

RCD TYPE B Product Overview

RCD TYPE B is a high-immunity RCD with a protection degree of IP20. It has a rated voltage of 2P: 230/240V AC; 4P: 400/415V AC and a rated storage temperature of -40℃~+70℃. Its rated residual operating current is 30mA, providing additional protection against electric shock.

The RCD TYPE B is made of high-quality materials, designed to be highly reliable and durable, providing maximum safety against electric shock and other electrical hazards. It is also designed to be easy to install and maintain.

The RCD TYPE B is ideal for residential and commercial applications, providing reliable and cost-effective protection against electric shock, electric fire hazards, and other electrical hazards. It is also suitable for industrial applications, where it can provide protection against high-power electric shock, electric fire hazards, and other electrical hazards.

The RCD TYPE B is an excellent choice for any application where safety and reliability are the primary requirements. It is designed to provide maximum protection against electric shock and other electrical hazards, while providing reliable and cost-effective protection.

Features:

  • Product Name: Residual Current Device TYPE B
  • Protection Degree: IP20
  • Rated Voltage: 2P: 230/240V AC; 4P: 400/415V AC
  • Rated Storage Temperature: -40℃~+70℃
  • Rated residual operating current I△n: 30mA, 100mA, 300mA, 500mA
  • Rated Insulation Voltage: 500V
  • Super immunised Residual Current Device

Applications:

HAROK's VKL11 RCD TYPE B is a residual current device that provides protection against electric shocks and fire caused by indirect contact and insulation faults. It is certified by CE, CB, NF, ISI and SEMKO with a minimum order quantity of 5000. It comes in a paper carton and takes 4-6 weeks for delivery after payment. Payment is accepted through FOB NINGBO or SHANGHAI with a supply ability of 100,000 PCS PER MONTH. It has a rated insulation voltage of 500V, protection degree of IP20, rated residual non-operating time of 0.3s, rated frequency of 50Hz/60Hz and rated current of 30mA.

Technical Parameters:

Parameter Specification
Product High immunity RCD, Super immunised Residual Current Device (RCD)
Rated current In 16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Residual Operating Time 0.03s
Rated residual operating current I△n 30mA, 100mA, 300mA, 500mA
Rated Current 30mA
Rated Storage Temperature -40℃~+70℃
Rated Residual Non-Operating Time 0.3s
Rated Frequency 50Hz/60Hz
Rated Insulation Voltage 500V
Protection Degree IP20
Rated conditional short-circuit current Inc 10kA

Customization:

Residual Current Device Type B HAROK VKL11

Brand Name: HAROK

Model Number: VKL11

Place of Origin: CHINA

Certification: CE, CB, NF, ISI, SEMKO

Minimum Order Quantity: 5000

Packaging Details: PAPER CARTON

Delivery Time: 4-6 weeks after payment

Payment Terms: FOB NINGBO or SHANGHAI

Supply Ability: 100,000 PCS PER MONTH

Operating Temperature: -25℃~+55℃

Rated Residual Non-Operating Time: 0.3s

Rated conditional short-circuit current Inc: 10kA

Product Name: Residual Current Device TYPE B

Rated Frequency: 50Hz/60Hz

Packing and Shipping:

Packaging and Shipping for Residual Current Device TYPE B:

The Residual Current DeviceTYPE B will be packaged in a sturdy cardboard box and sealed with a waterproof bag. The package will include instructions and safety warnings. The package will be shipped using a reliable courier service, ensuring that it arrives in perfect condition.

Inquiry Cart 0