Yueqing Vorax Electric CO.,LTD

Empowering Safety Energizing Efficiency Your Trusted Breaker Partner

Manufacturer from China
Verified Supplier
3 Years
Home / Products / RCD TYPE B /

VKL11 RCD Type B+

Contact Now
Yueqing Vorax Electric CO.,LTD
Visit Website
Province/State:zhejiang
Country/Region:china
Contact Person:MrWellkins Lew
Contact Now

VKL11 RCD Type B+

Ask Latest Price
Video Channel
Brand Name :HAROK
Model Number :VKL11
Place of Origin :CHINA
Certification :CE, CB, NF, ISI, SEMKO
MOQ :5000
Packaging Details :PAPER CARTON
Delivery Time :4-6 weeks after payment
Payment Terms :FOB NINGBO or SHANGHAI
Supply Ability :100,000 PCS PER MONTH
Rated Insulation Voltage :500V
Rated residual operating current I△n :30mA, 100mA, 300mA, 500mA
Rated current In :63A
Resistance to climatic conditions :IEC/EN 61008
Product Name :RCD TYPE B
Operating Temperature :-25℃~+55℃
Rated Frequency :50Hz/60Hz
Operation voltage electronic :50 – 264V AC
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

VKL11 RCD Type B+

  • General

1.1 Function

VKL11B RCD and VKL11B+ RCD is appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker.

Residual current circuit breaker type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

Residual current circuit breaker type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.

1.2 Selection

Detectable wave form

Type B

Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

Type B+

Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA

Tripping sensitivity

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide

protection against indirect contacts;

300mA - protection against indirect contacts, as well as fire hazard.

Tripping time

Instantaneous It ensures instantaneous tripping(without time-delay).

Short time delay

Selective (time delay)

1.3 Approvals and certificates

  • Technical parameters
Type B B+
Electrical
Design according to IEC/EN 62423, IEC/EN 61008-1, OVE E8601
VDE 0664-400
Current test marks as printed onto the device
Rated voltage Un

2P: 230/240V AC

4P: 400/415V AC

Rated frequency fn 50/60Hz
Mode of operation

"A type functionality: voltage independent

B and B+ type functionality: voltage dependent"

Operation voltage electronic 50 – 264V AC
Voltage range test circuit

2P: 184 – 264V AC

4P: 184 – 440V AC

Rated current In 40A

Rated residual

operating

current I△n

Instantaneous 30mA, 100mA, 300mA, 500mA 30mA, 100mA, 300mA
K-short time delayed (G, ASi) 30mA, 100mA, 300mA, 500mA 30mA, 100mA, 300mA
S- selective 100mA, 300mA, 500mA 100mA, 300mA
Sensitivity Alternating, pulsed and smooth direct currents
High frequency up to 1 kHZ High frequency up to 20kHZ
Rated insulation voltage Ui 500 V
Rated impulse withstand voltage Uimp 4 kV (1.2/50μs)
Rated conditional short-circuit current Inc 10 kA
Rated making and breaking capacity Im 1500 A
Peak withstand current

3 kA (8/20 μs) surge current proof

5 kA (8/20 μs) surge current proof for type S

Electrical isolation > 4 mm contact space

Maximum back-up fuse

In = 16-100A

Short circuit and overload protection

100 A gG/gL

Endurance

(operating cycles)

electrical components ≥ 2000
mechanical components ≥ 4000
Mechanical
Degree of protection IP20
Upper and lower terminals open mounted / lift terminals
Terminal capacity 1 - 25 mm2
Terminal torque 2 - 2.5 Nm
Busbar thickness 0.8 - 2 mm
Operating temperature -25°C ... +55°C
Storage- and transport temperature -40°C ... +70°C
Resistance to climatic conditions IEC/EN 61008
Contact position indicator mechanical red / green
Supply possibility top or bottom
Mounting position any

  • Special features regarding the use of SIQUENCE universal current-sensitive residual current device (Type B and Type B+)
    • Applications

3.1 Typical applications that are vulnerable to smooth DC residual currents:

- Frequency converters with a three-phase connection

- Medical equipment such as X-ray equipment or CT machines

- Photovoltaic or UPS systems

- Connection points (wall boxes, charging stations) for electric vehicles

- Elevator controllers

- Pipeline trace heating

- Test setups in laboratories

- Construction sites in accordance with BGI 608 information leaflet (Electronic equipment

on construction sites)

- Charging stations for battery-powered forklift trucks

- Cranes of all kinds

- Mixing plants if relevant loads are connected

- Variable-speed machine tools, such as milling and grinding machines or lathes

  • Wiring diagrams

VKL11 RCD Type B+VKL11 RCD Type B+

  • Tripping characteristics

.B type

VKL11 RCD Type B+

  • Dimensions (mm)
  • VKL11 RCD Type B+VKL11 RCD Type B+

Product Description:

RCD TYPE B is a high immunity Residual Current Device (RCD) designed to provide reliable protection against electric shock and fire hazards. It is a super immunised RCD with rated residual operating current of 30mA, 100mA, 300mA, 500mA, and rated conditional short-circuit current Inc of 10kA. This product is designed with IP20 protection degree, providing users with the highest safety protection. It is the perfect choice for those who value safety.

Features:

  • Product Name: RCD TYPE B
  • Rated Voltage: 2P: 230/240V AC; 4P: 400/415V AC
  • Rated Frequency: 50Hz/60Hz
  • Rated Insulation Voltage: 500V
  • Rated Residual Operating Current: 30mA, 100mA, 300mA, 500mA
  • Super immunised Residual Current Device to quickly detect and disconnect the electric circuit in case of a fault
  • Ideal for RESIDUAL CURRENT DEVICE protection against electric shock

Applications:

HAROK VKL11 Residual Current Device (RCD TYPE B) helps to protect people from electric shock and fire. This RCD is CE, CB, NF, ISI, SEMKO certified with a minimum order quantity of 5000. The packaging details include paper carton, and the delivery time is 4-6 weeks. The payment terms are FOB NINGBO or SHANGHAI. The supply ability is 100,000 PCS PER MONTH. The rated insulation voltage is 500V and the rated residual operating time is 0.03s with rated current of 16A, 25A, 32A, 40A, 63A, 80A, 100A. This Super immunised Residual Current Device (RCD TYPE B) has a rated impulse withstand voltage of 4kV.

Technical Parameters:

Technical Parameter Value
Product Name RCD TYPE B
Super immunised Residual Current Device Yes
Rated Current 16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated residual operating current I△n 30mA, 100mA, 300mA, 500mA
Rated Impulse Withstand Voltage 4kV
Rated Insulation Voltage 500V
Rated Frequency 50Hz/60Hz
Operating Temperature -25℃~+55℃
Rated Storage Temperature -40℃~+70℃

Customization:

Super immunised Residual Current Device RCD TYPE B

Brand Name: HAROK
Model Number: VKL11
Place of Origin: CHINA
Certification: CE, CB, NF, ISI, SEMKO
Minimum Order Quantity: 5000
Packaging Details: PAPER CARTON
Delivery Time: 4-6 weeks after payment
Payment Terms: FOB NINGBO or SHANGHAI
Supply Ability: 100,000 PCS PER MONTH
Rated current In: 16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Frequency: 50Hz/60Hz
Rated Residual Operating Current: 30mA, 100mA, 300mA, 500mA
Rated Impulse Withstand Voltage: 4kV
Rated Residual Operating Time: 0.03s

Packing and Shipping:

Packaging and Shipping of RCD TYPE B:

  • The RCD TYPE B shall be packed in an individual box containing the product and its necessary components.
  • The box shall be further packed in a corrugated cardboard carton.
  • The carton shall be marked with the product type, quantity, and other details relevant to the product.
  • The product must be shipped with appropriate padding and protection.
Inquiry Cart 0