Yueqing Vorax Electric CO.,LTD

Empowering Safety Energizing Efficiency Your Trusted Breaker Partner

Manufacturer from China
Verified Supplier
3 Years
Home / Products / Residual Current Device /

VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate

Contact Now
Yueqing Vorax Electric CO.,LTD
Visit Website
Province/State:zhejiang
Country/Region:china
Contact Person:MrWellkins Lew
Contact Now

VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate

Ask Latest Price
Video Channel
Brand Name :HAROK
Model Number :VML01
Place of Origin :CHINA
Certification :NF, SEMKO, VDE, KEMA, ISI, CE
MOQ :1000
Packaging Details :PAPER CARTON
Delivery Time :4-6 weeks after payment
Supply Ability :100,000 PCS PER MONTH
Rated Impact Endurance Voltage :2kV
Protection Class :IP20
Rated Residual Non-Operating Current :30mA, 100mA, 300mA
Certificate :CE, ISI, NF, SEMKO, VDE, KEMA
RatedCurrent :16A-100A
Product Name :Residual Current Device
Rated Short-Circuit Capacity :10kA
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

VML01 Residual Current Device(RCD) Type A Type AC Type ASi with Inmetro Certificate

VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate

1. General

1.1 Function

Control electric circuits.

Protect people against indirect contacts and additional protection against direct contacts.

Protect installations against fire hazard due to insulation faults.

Residual current circuit breakers are used in housing, tertiary sector and industry.

1.2 Selection

Detectable wave form

AC class

Tripping is ensured for slowly increasing sinusoidal AC residual currents

A class

Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.

ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

Note: Our ASi type includes G/KV function and Si function.

1.3 Approvals and certificates

We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

with the requirements.

1. Verification of the operating characteristic as per Seq. - D0 CL9.9

2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

3. High Voltage Test as per D.3 of Annex D

4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

Tripping sensitivity

10mA - precision instrument leakage protection and bathroom use.

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;

300mA/500mA - protection against indirect contacts, as well as fire hazard.

Tripping time

Instantaneous

It ensures instantaneous tripping(without time-delay).

Short time delay ASi

(High Immunity/ Avoid nuisance tripping &blinding)

It ensures any tripping at least 10ms.

Selective VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate

It ensures total discrimination with a non selective RCD placed downstream.

VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate

RCD | Residual Current Device

2. Technical parameters

Standard IEC/EN 61008-1 AS/NZS61008.1
Electrical features Model No. VML01
Poles 2P, 4P
Rated current In 16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Sensitivity I△n 10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
Rated voltage Ue 2P: 240V 4P: 415V
Insulation voltage Ui 415V
Rated frequency 50/60 Hz
Rated residual making and breaking capacity I△m 1500A
Short-circuit current Inc=I△c 6000A, 10000A
Type (wave form of the earth leakage sensed) AC, A, ASi, S
break time under I△n ≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
Rated impulse withstand voltage(1.2/50) Uimp 4kV
Dielectric test voltage at ind. Freq. for 1 min 2.5
Pollution degree 2
Mechanical features Electrical life ≥2000
Mechanical life ≥2000
Fault current indicator Yes
Terminal protection degree IP20

Ambient temperature (with

daily average≤35℃)

-25℃ to 50℃
Storage temperate -30℃ to 70℃
Installation Terminal connection type Cable/Pin-type busbar
Terminal size top/bottom for cable 25-35 mm²
18-3/18-2 AWG
Terminal size top/bottom for busbar 10/16 mm²
18-8/18-5 AWG
Tightening torque 2.5 N·m
22 In-Ibs.
Mounting On DIN rail EN 60715 (35mm) by means of fast clip device
Connection From top and bottom

3. Outline and installation dimensions (mm)

VML01 Type A Type AC Type ASi Residual Current Device With Inmetro Certificate

Product Description:

Residual Current Device (RCD) is a device designed to protect people and buildings from electrical shock and fire caused by an overload or short circuit. With a rated operating temperature of -25℃ to +40℃, protection class of IP20, rated residual operating time of 0.1s, and rated insulation voltage of 500V, this RCD provides superior safety and performance. It is the perfect choice for anyone looking for a reliable and durable RCD for their electrical system.

Features:

  • Product Name: Residual Current Device
  • Rated Residual Operating Current: 30mA, 100mA, 300mA
  • Rated Impulse Withstand Voltage: 4kV
  • Protection Class: IP20
  • Rated Current: 16A, 25A, 32A, 40A, 63A, 80A, 100A
  • Rated Voltage: 240/415V AC
  • Residual Current Device Type AC, A, ASi
  • Residual Current Device Certificates: Inmetro, ISI, CE, NF, UKCA, SEMKO

Applications:

Residual Current Device (RCD) is an essential device that provides protection from electric shock, fire, and other electrical hazards. The HAROK VML01 RCD is certified to meet the highest international standards with certifications from Inmetro, NF, SEMKO, VDE, KEMA, ISI, and CE. It has a rated impulse withstand voltage of 4kV, a rated insulation voltage of 500V, a rated residual operating current of 30mA-300mA, and a rated residual operating time of 0.1s. Produced by HAROK, the VML01 RCD offers superior quality and reliability for a wide range of applications.

The HAROK VML01 RCD is an ideal solution for industrial, commercial, and residential applications. It is suitable for use in residential homes, office buildings, and industrial facilities where it can provide protection against electrical shock. It is also suitable for use in medical facilities, laboratories, and other sensitive environments where it can provide protection from electrical hazards. The device is capable of detecting and interrupting small leakage currents, providing protection against shock, fire, and other electrical hazards.

The HAROK VML01 RCD is a compact and reliable device with a minimum order quantity of 1000, and a supply ability of 100,000 PCS per month. It is packaged in a paper carton and has a delivery time of 4-6 weeks after payment. With its superior quality and reliability, the HAROK VML01 RCD is the ideal solution for protecting against electric shock, fire, and other electrical hazards.

Technical Parameters:

Parameter Value
Rated Impact Endurance Voltage 2kV
Rated Residual Operating Current 30mA, 100mA, 300mA
Rated Humidity ≤95%RH
Rated Residual Operating Time 0.1s
Rated Voltage 230V AC
Rated Operating Temperature -25℃~+40℃
Rated Short-Circuit Capacity 10kA
Product Name Residual Current Device
Certificate CE, ISI, NF, SEMKO, VDE, KEMA, Inmetro
Residual Current Device Inmetro Type AC, Type A, Type ASi

Customization:

Residual Current Device
Brand Name: HAROK
Model Number: VML01

Place of Origin: CHINA

Certification: NF, SEMKO, VDE, KEMA, ISI, CE, Inmetro

Minimum Order Quantity: 1000pcs

Packaging Details: PAPER CARTON

Delivery Time: 4-6 weeks after payment

Supply Ability: 100,000 PCS PER MONTH

Rated Operating Temperature: -25℃~+40℃

Rated Impact Endurance Voltage: 2kV

Rated Current: 16A-100A

Rated Voltage: 240/415V AC

Packing and Shipping:

Packaging and Shipping for Residual Current Device

Residual Current Devices will be packaged and shipped in accordance with the following guidelines:

  • Product will be packaged in a box with appropriate cushioning material.
  • The box will be labeled with the product name, model number, and shipping address.
  • The package will be sealed with tape to ensure it remains closed during transit.
  • The package will be shipped via a reputable carrier, with tracking and insurance.
```
Inquiry Cart 0