VKL11 Residual Current Device RCD Type S Selective Time Delay

Ask Latest Price
Video Channel
Brand Name :HAROK
Model Number :VKL11
Place of Origin :CHINA
Certification :NF, SEMKO, VDE, KEMA, ISI, CE
MOQ :1000
Packaging Details :PAPER CARTON
Delivery Time :4-6 weeks after payment
Supply Ability :100,000 PCS PER MONTH
Rated Voltage :240/415V AC
Protection Class :IP20
Rated Humidity :≤95%RH
Rated Residual Non-Operating Current :30mA, 100mA, 300mA
Rated Insulation Voltage :500V
Certificate :CE, ISI, NF, SEMKO, VDE, KEMA
Rated Operating Temperature :-25℃~+40℃
Product Name :Residual Current Device
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

VKL11 Residual Current Device (RCD) type S Selective time delay
VKL11 Residual Current Device RCD Type S Selective Time Delay

1. General

1.1 Function

Control electric circuits.

Protect people against indirect contacts and additional protection against direct contacts.

Protect installations against fire hazard due to insulation faults.

Residual current circuit breakers are used in housing, tertiary sector and industry.


1.2 Selection

Detectable wave form

RCD Type Suitable for electrical networks with
Pulsated DC current Harmonics Switching surges
AC CLASS No No No
A CLASS Yes No No
S, ASi CLASS Yes Yes Yes

A Class RCD may not work satisfactorily in electrical network distributed by harmonics & switching transients and may give nuisance triping.

AC class

Tripping is ensured for slowly increasing sinusoidal AC residual currents

A class

Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.

ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

Note: Our ASi type includes G/KV function and Si function.


1.3 Approvals and certificates

We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

with the requirements.

1. Verification of the operating characteristic as per Seq. - D0 CL9.9

2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

3. High Voltage Test as per D.3 of Annex D

4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

Tripping sensitivity
10mA - precision instrument leakage protection and bathroom use.
30mA - additional protection against direct contact.
100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;
300mA/500mA - protection against indirect contacts, as well as fire hazard.
Tripping time
Instantaneous
It ensures instantaneous tripping(without time-delay).
Short time delay ASi
(High Immunity/ Avoid nuisance tripping &blinding)
It ensures any tripping at least 10ms.
Selective VKL11 Residual Current Device RCD Type S Selective Time Delay
It ensures total discrimination with a non selective RCD placed downstream.
VKL11 Residual Current Device RCD Type S Selective Time Delay



RCD | Residual Current Device

2. Technical parameters

Standard IEC/EN 61008-1 AS/NZS61008.1
Electrical features Model No. VKL11
Poles 2P, 4P
Rated current In 16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Sensitivity I△n 10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
Rated voltage Ue 2P: 240V 4P: 415V
Insulation voltage Ui 415V
Rated frequency 50/60 Hz
Rated residual making and breaking capacity I△m 1500A
Short-circuit current Inc=I△c 6000A, 10000A
Type (wave form of the earth leakage sensed) AC, A, ASi, S
break time under I△n ≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
Rated impulse withstand voltage(1.2/50) Uimp 4kV
Dielectric test voltage at ind. Freq. for 1 min 2.5
Pollution degree 2
Mechanical features Electrical life ≥2000
Mechanical life ≥2000
Fault current indicator Yes
Terminal protection degree IP20

Ambient temperature (with

daily average≤35℃)

-25℃ to 50℃
Storage temperate -30℃ to 70℃
Installation Terminal connection type Cable/Pin-type busbar
Terminal size top/bottom for cable 25-35 mm²
18-3/18-2 AWG
Terminal size top/bottom for busbar 10/16 mm²
18-8/18-5 AWG
Tightening torque 2.5 N·m
22 In-Ibs.
Mounting On DIN rail EN 60715 (35mm) by means of fast clip device
Connection From top and bottom



3. Outline and installation dimensions (mm)

VKL11 Residual Current Device RCD Type S Selective Time DelayVKL11 Residual Current Device RCD Type S Selective Time Delay

Product Description:

Residual Current Device

Residual Current Device (RCD) is a safety device designed to protect people from electric shock and other potential danger. It can detect the presence of a fault current and quickly disconnect the circuit, so that the fault current is interrupted to protect the safety of people from electric shock.

This product is certified CE, ISI, NF, SEMKO, VDE, KEMA and has a rated operating temperature of -25°C to +40°C. The rated current is 30mA and the rated short-circuit capacity is 10kA.

Residual Current Device is an important safety device in electrical system and it is widely used in many places such as industrial plants, office buildings, homes, etc.

Features:

  • Product Name: Residual Current Device
  • Rated Residual Non-Operating Time: 5s
  • Rated Residual Operating Current: 30mA, 100mA, 300mA
  • Rated Current: 16A, 20A, 25A, 32A, 40A, 63A, 80A, 100A
  • Rated Residual Operating Time: 0.1s
  • Rated Operating Temperature: -25℃~+40℃
  • Type: AC, A, ASi, B, B+, F

Applications:

HAROK VKL11 Residual Current Device is designed to detect and trip on leakage current in electrical wiring systems in order to protect people and other devices from potential electric shock. It is ideal for use in domestic, commercial and industrial applications. The device is certified by NF, SEMKO, VDE, KEMA, ISI, CE and has a minimum order quantity of 1000. Delivery time is 4-6 weeks after payment and the company has a supply ability of 100,000 PCS PER MONTH. The Rated Impulse Withstand Voltage is 4kV.

The HAROK VKL11 Residual Current Device is available in three types: Type AC, Type A and Type ASi. It has a wide range of applications from domestic to commercial and industrial applications. The device is designed to detect and trip on leakage current and protect people and other devices from potential electric shock. The product comes in a PAPER CARTON packaging and is easy to install and maintain. It is a reliable and cost-effective solution for protecting people and their property from electrical hazards.

Technical Parameters:

Parameter Value
Product Name Residual Current Device
Type AC, Type A, Type ASi
Rated Impulse Withstand Voltage 4kV
Rated Frequency 50/60Hz
Rated Current 16A, 20A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Insulation Voltage 500V
Certificate CE, ISI, NF, SEMKO, VDE, KEMA
Protection Class IP20
Rated Residual Operating Current 30mA, 100mA, 300mA

Customization:

Residual Current Device Type UL1053 (HAROK VKL11)
  • Brand Name: HAROK
  • Model Number: VKL11
  • Place of Origin: CHINA
  • Certification: NF, SEMKO, VDE, KEMA, ISI, CE
  • Minimum Order Quantity: 1000
  • Packaging Details: PAPER CARTON
  • Delivery Time: 4-6 weeks after payment
  • Supply Ability: 100,000 PCS PER MONTH
  • Rated Residual Operating Current: 30mA, 100mA, 300mA
  • Rated Humidity: ≤95%RH
  • Rated Operating Temperature: -25℃~+40℃
  • Rated Current: 16A, 20A, 25A, 32A, 40A, 63A, 80A, 100A
  • Rated Impulse Withstand Voltage: 4kV

Packing and Shipping:

Packaging and Shipping of Residual Current Device

The Residual Current Device (RCD) should be packaged and shipped in a secure manner to protect it from damage caused by external factors. The packaging material should be shock absorbent and suitable for shipping given its size and weight.

During packaging, the RCD should be placed in a box and secured with bubble wrap or packing peanuts to minimize movement while in transit. If the RCD is to be shipped internationally, it should also be packaged in a way that meets all international customs and export regulations.

The RCD should be shipped via a reliable carrier with a tracking system to ensure that it is delivered safely and in a timely manner. Additionally, it is important to purchase the appropriate level of insurance to cover any potential damage or loss during shipment.