Yueqing Vorax Electric CO.,LTD

Empowering Safety Energizing Efficiency Your Trusted Breaker Partner

Manufacturer from China
Verified Supplier
2 Years
Home / Products / Residual Current Device /

VKL11 Certified NF Residual Current Device Type EV Rcd

China VKL11 Certified NF Residual Current Device Type EV Rcd wholesale
  • China VKL11 Certified NF Residual Current Device Type EV Rcd wholesale
  • China VKL11 Certified NF Residual Current Device Type EV Rcd wholesale
  • China VKL11 Certified NF Residual Current Device Type EV Rcd wholesale

VKL11 Certified NF Residual Current Device Type EV Rcd

Ask Latest Price
Video Channel
Brand Name :HAROK
Model Number :VKL11
Place of Origin :CHINA
Certification :NF, SEMKO, VDE, KEMA, ISI, CE
MOQ :1000
Packaging Details :PAPER CARTON
Delivery Time :4-6 weeks after payment
Supply Ability :100,000 PCS PER MONTH
Rated Short-Circuit Capacity :10kA
Rated Voltage :240/415V AC
Rated Residual Non-Operating Current :30mA, 100mA, 300mA
Protection Class :IP20
Rated Impulse Withstand Voltage :4kV
Rated Current :16A, 20A, 25A, 32A, 40A, 63A, 80A, 100A
TYPE :A EV
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

VKL11 Residual Current Device (RCD) type EV


1. General
VKL11 Certified NF Residual Current Device Type EV Rcd

1.1 Function

Residual Current Device VKL11 TYPE A EV (RCD TYPE A EV) is the Type EV RCCB which has been developed specifically for EV charging systems and can detect AC and DC residual currents in accordance with the requirements of EN61008-1 and IEC62955(RDC-PD:Residual Direct Current Protective Device )

VKL11 Type A EV RDC-PD/RCD is designed specifically for use in Mode 3 charging applications.

1.2 Selection

Detectable wave form AC class

Tripping is ensured for slowly increasing sinusoidal AC

residual currents

A class

Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.

Smooth DC 6mA

smooth DC residual currents (switch-off at max 6 mA)

VKL11 Certified NF Residual Current Device Type EV Rcd

1.3 Approvals and certificates :UKCA,CE

Tripping sensitivity

30mA - 50Hz sinusoidal AC ; Pulsating DC

Smooth DC ≥ 6 mA (RDC-PD)

Tripping time

Instantaneous

It ensures instantaneous tripping(without time-delay).



RCD | Residual Current Device

2. Technical parameters

Standard IEC/EN 61008-1,IEC 62955
Electrical features Model No. VKL11 A EV
Poles 2P, 4P
Rated current In 16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Sensitivity I△n 10mA(2P/4P 16A-40A), 30mA, 100mA, 300mA
DC tripping threshold 6mA
Rated voltage Ue 2P: 240V 4P: 415V
Insulation voltage Ui 500V
Rated frequency 50/60 Hz

Rated residual making and

breaking capacity I△m

500A (In=16A, 25A, 32A, 40A)
630A(In=63A), 800A(In=80A), 1000A(In=100A)
Short-circuit current Inc=I△c 6000A, 10000A
Type (wave form of the earth leakage sensed)

AC, A

Smooth DC 6mA

Tripping time Instantaneous
break time under I△n

≤100ms

(Normal type)

Rated impulse withstand voltage(1.2/50) Uimp 6kV
Dielectric test voltage at ind. Freq. for 1 min 2.5
Pollution degree 2
Mechanical features Electrical life ≥2000
Mechanical life ≥2000
Fault current indicator Yes
Terminal protection degree IP20

Ambient temperature (with

daily average≤35℃)

-25℃ to 55℃
Storage temperature -40℃ to 70℃
Installation Terminal connection type Cable/Pin-type busbar
Terminal size top/bottom for cable 25-35 mm²
18-3/18-2 AWG
Terminal size top/bottom for busbar 10/16 mm²
18-8/18-5 AWG
Tightening torque 2.5 N·m
22 In-Ibs.
Mounting On DIN rail EN 60715 (35mm) by means of fast clip device
Connection From top and bottom
Standard EN61008-1 ,IEC62955



3. Outline and installation dimensions (mm)

VKL11 Certified NF Residual Current Device Type EV RcdVKL11 Certified NF Residual Current Device Type EV Rcd

Product Description:

A Residual Current Device (RCD) Inmetro 500V is a protective device designed to quickly disconnect the electrical circuit when a fault current is detected. This device is rated to a voltage of 500V and a frequency of 50/60Hz, with a rated residual operating time of 0.1s and a rated voltage of 240/415V AC. It is also rated to a protection class of IP20. This device is essential for the safety of your electrical system, and can help prevent serious injury or even death due to electrical shock.

The RCD Inmetro 500V is a reliable and robust safety device, designed with advanced technology to protect against electrical shocks and fires. It offers a wide range of features, including a high level of electrical insulation, superior short-circuit protection, and overload protection. It has been tested and certified by Inmetro to meet the highest safety standards, and is suitable for both commercial and residential applications.

The RCD Inmetro 500V is an essential device for protecting both people and property, and is an important part of any electrical system. It is easy to install and maintain, and can provide peace of mind that your electrical system is well protected. So if you're looking for reliable electrical safety, the RCD Inmetro 500V is the perfect solution.

Features:

  • Product Name: Residual Current Device
  • Type: Type EV
  • Rated Impact Endurance Voltage: 2kV
  • Rated Frequency: 50/60Hz
  • Rated Impulse Withstand Voltage: 4kV
  • Certificate: CE, ISI, NF, SEMKO, VDE, KEMA

Applications:

HAROK VKL11 Residual Current Device (RCD) is designed to protect people from electric shock and provide an extra layer of safety in electrical circuits. It detects and quickly breaks an electrical circuit when a leakage of current is detected, which helps to prevent electric shock, fire and other hazards. This RCD meets the latest UL1053 standard and is certified to NF, SEMKO, VDE, KEMA, ISI and CE standards. It has a rated impact endurance voltage of 2kV, a rated residual operating current of 30mA, a rated voltage of 240/415V AC, a rated residual operating time of 0.1s, and a rated short-circuit capacity of 10KA. It is perfect for indoor use in residential, commercial and industrial settings. Our RCD is available in minimum orders of 1000 pieces and comes in a paper carton for easy storage and transport. We can supply up to 100,000 pieces per month with delivery within 4-6 weeks of payment.

Technical Parameters:

Parameter Name Parameter Value
Product Name Residual Current Device
Rated Short-Circuit Capacity 10kA
Rated Voltage 240/415V AC
Rated Current 16A-100A
Rated Impulse Withstand Voltage 4kV
Rated Operating Temperature -25℃~+40℃
Certificate CE, ISI, NF, SEMKO, VDE, KEMA
Rated Insulation Voltage 500V
Residual Current Device Type TYPE A EV

Customization:

Residual Current Device with Type A EV

Brand Name: HAROK

Model Number: VKL11

Place of Origin: CHINA

Certification: NF, SEMKO, VDE, KEMA, ISI, CE

Minimum Order Quantity: 1000

Packaging Details: PAPER CARTON

Delivery Time: 4-6 weeks after payment

Supply Ability: 100,000 PCS PER MONTH

Certificate: CE, ISI, NF, SEMKO, VDE, KEMA

Rated Voltage: 240/415V AC

Rated Frequency: 50/60Hz

Rated Humidity: ≤95%RH

Rated Residual Operating Current: 30mA-300mA

Features:

Residual Current Device Type A EV

Packing and Shipping:

Packaging and Shipping of Residual Current Device

We use high-quality materials to package and ship the residual current device. Our package is strong and secure to ensure that the product reaches the destination in perfect condition.

Packaging
  • The residual current device is placed in a strong cardboard box.
  • The box is filled with foam to provide extra protection.
  • The box is sealed with tape to ensure that it is secure.
Shipping
  • The package is shipped via a reputable shipping company.
  • The package is tracked to ensure that it is delivered safely and on time.
  • Delivery is insured to ensure that the customer is covered in the event of any damage or loss.
China VKL11 Certified NF Residual Current Device Type EV Rcd for sale

VKL11 Certified NF Residual Current Device Type EV Rcd

Inquiry Cart 0