Yueqing Vorax Electric CO.,LTD

Empowering Safety Energizing Efficiency Your Trusted Breaker Partner

Manufacturer from China
Verified Supplier
3 Years
Home / Products / RCCB TYPE B /

High Immunity RCCB TYPE B- Rated Voltage Un 2P 230/240V~ And 4P 400/415V~ With Superior Mechanical Endurance Of ≥ 4000

Contact Now
Yueqing Vorax Electric CO.,LTD
Visit Website
Province/State:zhejiang
Country/Region:china
Contact Person:MrWellkins Lew
Contact Now

High Immunity RCCB TYPE B- Rated Voltage Un 2P 230/240V~ And 4P 400/415V~ With Superior Mechanical Endurance Of ≥ 4000

Ask Latest Price
Video Channel
Brand Name :HAROK
Model Number :VKL11
Place of Origin :CHINA
Standard :IEC/EN 62423, IEC/EN 61008-1, OVE E8601
Product Name :RCCB TYPE B
Rated current In :16A, 25A, 32A, 40A, 63A, 80A, 100A
Electrical Endurance :≥ 2000
Rated voltage Un :2P 230/240V~; 4P 400/415V~
Rated Frequency :50/60Hz
Rated insulation voltage Ui :500V
Mechanical Endurance :≥ 4000
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

HAROK DATASHEET

High immunity RCCB TYPE B 63A Residual Current Circuit Breaker

1. General

1.1 Function

Type B RCCBs (Residual Current Circuit Breakers) are primarily used for protecting against pulsating DC residual currents, high-frequency AC residual currents, and smooth DC residual currents in specific applications such as charging electric vehicles and renewable energy sources. They are also used in installations where there is a possibility of smooth DC residual currents, for example, IT networks and UPS systems.

Type B+ RCCBs (Residual Current Circuit Breakers) are mainly used in applications where high-frequency and high-pulse DC residual currents are present, such as photovoltaic (PV) generators, electric vehicles, battery systems, and welding equipment. The Type B+ RCCBs offer additional protection against DC residual currents compared to standard Type B RCCBs.

VKL11B RCCB and VKL11B+ RCCB is appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker.

Residual current circuit breaker type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

Residual current circuit breaker type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.

1.2 Selection

Detectable wave form

Type B High Immunity RCCB TYPE B- Rated Voltage Un 2P 230/240V~ And 4P 400/415V~ With Superior Mechanical Endurance Of ≥ 4000

Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

Type B+High Immunity RCCB TYPE B- Rated Voltage Un 2P 230/240V~ And 4P 400/415V~ With Superior Mechanical Endurance Of ≥ 4000High Immunity RCCB TYPE B- Rated Voltage Un 2P 230/240V~ And 4P 400/415V~ With Superior Mechanical Endurance Of ≥ 4000

Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA

Tripping sensitivity

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide protection against indirect contacts;

300mA - protection against indirect contacts, as well as fire hazard.

Tripping time

Instantaneous It ensures instantaneous tripping(without time-delay).

Short time delay

Selective (time delay)

1.3 Approvals and certificates

High Immunity RCCB TYPE B- Rated Voltage Un 2P 230/240V~ And 4P 400/415V~ With Superior Mechanical Endurance Of ≥ 4000

RCCB | Residual Current Circuit Breaker

2. Technical parameters

Type B B+
Electrical
Design according to IEC/EN 62423, IEC/EN 61008-1, OVE E8601
VDE 0664-400
Current test marks as printed onto the device
Rated voltage Un

2P: 230/240V AC

4P: 400/415V AC

Rated frequency fn 50/60Hz
Mode of operation

"A type functionality: voltage independent

B and B+ type functionality: voltage dependent"

Operation voltage electronic 50 – 264V AC
Voltage range test circuit

2P: 184 – 264V AC

4P: 184 – 440V AC

Rated current In 63A

Rated residual

operating

current I△n

Instantaneous 30mA, 100mA, 300mA, 500mA 30mA, 100mA, 300mA
K-short time delayed (G, ASi) 30mA, 100mA, 300mA, 500mA 30mA, 100mA, 300mA
S- selective 100mA, 300mA, 500mA 100mA, 300mA
Sensitivity Alternating, pulsed and smooth direct currents
High frequency up to 1 kHZ High frequency up to 20kHZ
Rated insulation voltage Ui 500 V
Rated impulse withstand voltage Uimp 4 kV (1.2/50μs)
Rated conditional short-circuit current Inc 10 kA
Rated making and breaking capacity Im 1500 A
Peak withstand current

3 kA (8/20 μs) surge current proof

5 kA (8/20 μs) surge current proof for type S

Electrical isolation > 4 mm contact space

Maximum back-up fuse

In = 16-100A

Short circuit and overload protection

100 A gG/gL

Endurance

(operating cycles)

electrical components ≥ 2000
mechanical components ≥ 4000
Mechanical
Degree of protection IP20
Upper and lower terminals open mounted / lift terminals
Terminal capacity 1 - 25 mm2
Terminal torque 2 - 2.5 Nm
Busbar thickness 0.8 - 2 mm
Operating temperature -25°C ... +55°C
Storage- and transport temperature -40°C ... +70°C
Resistance to climatic conditions IEC/EN 61008
Contact position indicator mechanical red / green
Supply possibility top or bottom
Mounting position any

3. Special features regarding the use of SIQUENCE universal current-sensitive residual current circuit breaker (Type B and Type B+)

3.1 Applications

Typical applications that are vulnerable to smooth DC residual currents:

- Frequency converters with a three-phase connection

- Medical equipment such as X-ray equipment or CT machines

- Photovoltaic or UPS systems

- Connection points (wall boxes, charging stations) for electric vehicles

- Elevator controllers

- Pipeline trace heating

- Test setups in laboratories

- Construction sites in accordance with BGI 608 information leaflet (Electronic equipment on construction sites)

- Charging stations for battery-powered forklift trucks

- Cranes of all kinds

- Mixing plants if relevant loads are connected

- Variable-speed machine tools, such as milling and grinding machines or lathes

4. Wiring diagrams

High Immunity RCCB TYPE B- Rated Voltage Un 2P 230/240V~ And 4P 400/415V~ With Superior Mechanical Endurance Of ≥ 4000High Immunity RCCB TYPE B- Rated Voltage Un 2P 230/240V~ And 4P 400/415V~ With Superior Mechanical Endurance Of ≥ 4000

5. Tripping characteristics

B type

High Immunity RCCB TYPE B- Rated Voltage Un 2P 230/240V~ And 4P 400/415V~ With Superior Mechanical Endurance Of ≥ 4000

6. Dimensions (mm)

High Immunity RCCB TYPE B- Rated Voltage Un 2P 230/240V~ And 4P 400/415V~ With Superior Mechanical Endurance Of ≥ 4000High Immunity RCCB TYPE B- Rated Voltage Un 2P 230/240V~ And 4P 400/415V~ With Superior Mechanical Endurance Of ≥ 4000

Product Description:

RCCB TYPE B is a high-immunity residual current circuit breaker (RCCB) designed for 2P 230/240V~ and 4P 400/415V~ power supply. It has a rated impulse withstand voltage of 4 KV (1.2/50μs) and is available in 16A, 25A, 32A, 40A, 63A, 80A, 100A rated currents. It is designed and manufactured to comply with IEC/EN 62423, IEC/EN 61008-1, OVE E8601 standards, making it a super immunised RCCB.

This RCCB TYPE B is an ideal choice for protecting against electric shock caused by indirect contact. It is designed to detect leakage current and quickly shut off the power supply to protect people and equipment from electrical shock and fire hazards. It also has a wide range of applications, from residential, commercial and industrial to telecommunications and medical equipment.

The RCCB TYPE B is a reliable, safe and cost-effective solution for residual current protection. It is easy to install and maintain, and is backed by a 1-year warranty for peace of mind.

Features:

  • Product Name: Super immunised RCCB TYPE B
  • Electrical Endurance: ≥ 2000
  • Mechanical Endurance: ≥ 4000
  • Rated Frequency: 50/60Hz
  • Rated impulse withstand voltage Uimp: 4 KV (1.2/50μs)
  • Rated voltage Un: 2P 230/240V~; 4P 400/415V~

Applications:

The high-immunity RCCB TYPE B from HAROK with model number VKL11 is an essential device for providing safety in domestic and industrial electrical systems. It has a rated frequency of 50/60Hz and a rated voltage Un of 2P 230/240V~; 4P 400/415V~. It is compliant with the international standards IEC/EN 62423, IEC/EN 61008-1, OVE E8601, and has an electrical endurance of ≥ 2000. It also provides a degree of protection IP20 and is certified as super immunised RCCB for its high immunity. It is manufactured in CHINA and is available at an affordable price.

Technical Parameters:

参数 详细描述
RCCB TYPE B Super immunised RCCB
Rated Frequency 50/60Hz
Rated current In 16A, 25A, 32A, 40A, 63A, 80A, 100A
Electrical Endurance ≥ 2000
Rated residual operating current I△n 30mA, 100mA, 300mA, 500mA (Instantaneous & K-short Time Delayed (G, ASi)); 100mA, 300mA, 500mA (100mA, 300mA, 500mA)
Degree of protection IP20
Mechanical Endurance ≥ 4000
Busbar thickness 0.8 - 2 Mm
Sensitivity Alternating, Pulsed And Smooth Direct Currents (High Frequency Up To 1 KHZ)
Rated making and breaking capacity Im 1500A
Rated voltage Un 2P 230/240V~; 4P 400/415V~

Customization:

HAROK VKL11 High Immunity RCCB
Super immunised RCCB

Brand Name: HAROK
Model Number: VKL11
Place of Origin: CHINA
Standard: IEC/EN 62423, IEC/EN 61008-1, OVE E8601
Rated voltage Un: 2P 230/240V~; 4P 400/415V~
Electrical Endurance: ≥ 2000
Rated making and breaking capacity Im: 1500A
Rated residual operating current I△n: 30mA, 100mA, 300mA, 500mA (Instantaneous & K-short Time Delayed (G, ASi)); 100mA, 300mA, 500mA (100mA, 300mA, 500mA)

HAROK VKL11 High Immunity RCCB is a super immunised Residual Current Circuit Breaker, meeting IEC/EN 62423, IEC/EN 61008-1, OVE E8601 standards. With a rated voltage of 2P 230/240V~; 4P 400/415V~, electrical endurance of ≥ 2000, rated making and breaking capacity of 1500A, and rated residual operating current of 30mA, 100mA, 300mA, 500mA (Instantaneous & K-short Time Delayed (G, ASi)); 100mA, 300mA, 500mA (100mA, 300mA, 500mA).

Packing and Shipping:

RCCB TYPE B Packaging and Shipping:

  • The product is shipped in a sturdy cardboard box.
  • The box is sealed with tape.
  • The box contains the product, instruction manual, and other necessary accessories.
  • The product is wrapped in bubble wrap for extra protection.

Inquiry Cart 0