Add to Cart
High immunity RCCB TYPE B 63A Residual Current Circuit Breaker
1. General
1.1 Function
Type B RCCBs (Residual Current Circuit Breakers) are primarily used for protecting against pulsating DC residual currents, high-frequency AC residual currents, and smooth DC residual currents in specific applications such as charging electric vehicles and renewable energy sources. They are also used in installations where there is a possibility of smooth DC residual currents, for example, IT networks and UPS systems.
Type B+ RCCBs (Residual Current Circuit Breakers) are mainly used in applications where high-frequency and high-pulse DC residual currents are present, such as photovoltaic (PV) generators, electric vehicles, battery systems, and welding equipment. The Type B+ RCCBs offer additional protection against DC residual currents compared to standard Type B RCCBs.
VKL11B RCCB and VKL11B+ RCCB is appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker.
Residual current circuit breaker type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.
Residual current circuit breaker type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.
They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.
1.2 Selection
Detectable wave form
Type B
Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.
Type B+
Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA
Tripping sensitivity
30mA - additional protection against direct contact.
100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide protection against indirect contacts;
300mA - protection against indirect contacts, as well as fire hazard.
Tripping time
Instantaneous It ensures instantaneous tripping(without time-delay).
Short time delay
Selective (time delay)
1.3 Approvals and certificates
RCCB | Residual Current Circuit Breaker
2. Technical parameters
Type | B | B+ | ||
Electrical | ||||
Design according to | IEC/EN 62423, IEC/EN 61008-1, OVE E8601 | |||
VDE 0664-400 | ||||
Current test marks as printed onto the device | ||||
Rated voltage Un | 2P: 230/240V AC 4P: 400/415V AC | |||
Rated frequency fn | 50/60Hz | |||
Mode of operation | "A type functionality: voltage independent B and B+ type functionality: voltage dependent" | |||
Operation voltage electronic | 50 – 264V AC | |||
Voltage range test circuit | 2P: 184 – 264V AC 4P: 184 – 440V AC | |||
Rated current In | 63A | |||
Rated residual operating current I△n | Instantaneous | 30mA, 100mA, 300mA, 500mA | 30mA, 100mA, 300mA | |
K-short time delayed (G, ASi) | 30mA, 100mA, 300mA, 500mA | 30mA, 100mA, 300mA | ||
S- selective | 100mA, 300mA, 500mA | 100mA, 300mA | ||
Sensitivity | Alternating, pulsed and smooth direct currents | |||
High frequency up to 1 kHZ | High frequency up to 20kHZ | |||
Rated insulation voltage Ui | 500 V | |||
Rated impulse withstand voltage Uimp | 4 kV (1.2/50μs) | |||
Rated conditional short-circuit current Inc | 10 kA | |||
Rated making and breaking capacity Im | 1500 A | |||
Peak withstand current | 3 kA (8/20 μs) surge current proof 5 kA (8/20 μs) surge current proof for type S | |||
Electrical isolation | > 4 mm contact space | |||
Maximum back-up fuse In = 16-100A | Short circuit and overload protection 100 A gG/gL | |||
Endurance (operating cycles) | electrical components | ≥ 2000 | ||
mechanical components | ≥ 4000 | |||
Mechanical | ||||
Degree of protection | IP20 | |||
Upper and lower terminals | open mounted / lift terminals | |||
Terminal capacity | 1 - 25 mm2 | |||
Terminal torque | 2 - 2.5 Nm | |||
Busbar thickness | 0.8 - 2 mm | |||
Operating temperature | -25°C ... +55°C | |||
Storage- and transport temperature | -40°C ... +70°C | |||
Resistance to climatic conditions | IEC/EN 61008 | |||
Contact position indicator | mechanical red / green | |||
Supply possibility | top or bottom | |||
Mounting position | any |
3. Special features regarding the use of SIQUENCE universal current-sensitive residual current circuit breaker (Type B and Type B+)
3.1 Applications
Typical applications that are vulnerable to smooth DC residual currents:
- Frequency converters with a three-phase connection
- Medical equipment such as X-ray equipment or CT machines
- Photovoltaic or UPS systems
- Connection points (wall boxes, charging stations) for electric vehicles
- Elevator controllers
- Pipeline trace heating
- Test setups in laboratories
- Construction sites in accordance with BGI 608 information leaflet (Electronic equipment on construction sites)
- Charging stations for battery-powered forklift trucks
- Cranes of all kinds
- Mixing plants if relevant loads are connected
- Variable-speed machine tools, such as milling and grinding machines or lathes
4. Wiring diagrams
5. Tripping characteristics
B type
6. Dimensions (mm)
RCCB TYPE B is a high-immunity residual current circuit breaker (RCCB) designed for 2P 230/240V~ and 4P 400/415V~ power supply. It has a rated impulse withstand voltage of 4 KV (1.2/50μs) and is available in 16A, 25A, 32A, 40A, 63A, 80A, 100A rated currents. It is designed and manufactured to comply with IEC/EN 62423, IEC/EN 61008-1, OVE E8601 standards, making it a super immunised RCCB.
This RCCB TYPE B is an ideal choice for protecting against electric shock caused by indirect contact. It is designed to detect leakage current and quickly shut off the power supply to protect people and equipment from electrical shock and fire hazards. It also has a wide range of applications, from residential, commercial and industrial to telecommunications and medical equipment.
The RCCB TYPE B is a reliable, safe and cost-effective solution for residual current protection. It is easy to install and maintain, and is backed by a 1-year warranty for peace of mind.
The high-immunity RCCB TYPE B from HAROK with model number VKL11 is an essential device for providing safety in domestic and industrial electrical systems. It has a rated frequency of 50/60Hz and a rated voltage Un of 2P 230/240V~; 4P 400/415V~. It is compliant with the international standards IEC/EN 62423, IEC/EN 61008-1, OVE E8601, and has an electrical endurance of ≥ 2000. It also provides a degree of protection IP20 and is certified as super immunised RCCB for its high immunity. It is manufactured in CHINA and is available at an affordable price.
参数 | 详细描述 |
---|---|
RCCB TYPE B | Super immunised RCCB |
Rated Frequency | 50/60Hz |
Rated current In | 16A, 25A, 32A, 40A, 63A, 80A, 100A |
Electrical Endurance | ≥ 2000 |
Rated residual operating current I△n | 30mA, 100mA, 300mA, 500mA (Instantaneous & K-short Time Delayed (G, ASi)); 100mA, 300mA, 500mA (100mA, 300mA, 500mA) |
Degree of protection | IP20 |
Mechanical Endurance | ≥ 4000 |
Busbar thickness | 0.8 - 2 Mm |
Sensitivity | Alternating, Pulsed And Smooth Direct Currents (High Frequency Up To 1 KHZ) |
Rated making and breaking capacity Im | 1500A |
Rated voltage Un | 2P 230/240V~; 4P 400/415V~ |
Brand Name: HAROK
Model Number: VKL11
Place of Origin: CHINA
Standard: IEC/EN 62423, IEC/EN 61008-1, OVE E8601
Rated voltage Un: 2P 230/240V~; 4P 400/415V~
Electrical Endurance: ≥ 2000
Rated making and breaking capacity Im: 1500A
Rated residual operating current I△n: 30mA, 100mA, 300mA, 500mA (Instantaneous & K-short Time Delayed (G, ASi)); 100mA, 300mA, 500mA (100mA, 300mA, 500mA)
HAROK VKL11 High Immunity RCCB is a super immunised Residual Current Circuit Breaker, meeting IEC/EN 62423, IEC/EN 61008-1, OVE E8601 standards. With a rated voltage of 2P 230/240V~; 4P 400/415V~, electrical endurance of ≥ 2000, rated making and breaking capacity of 1500A, and rated residual operating current of 30mA, 100mA, 300mA, 500mA (Instantaneous & K-short Time Delayed (G, ASi)); 100mA, 300mA, 500mA (100mA, 300mA, 500mA).
RCCB TYPE B Packaging and Shipping: